User manual TANDBERG 220-420LTO - User guide TANDBERG 220-420LTO - English - Diplodocs

DISCLAIMER TO DOWNLOAD THE USER GUIDE TANDBERG 220-420LTO

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TANDBERG 220-420LTO will begin.

You agree to use the Manual in accordance with the terms and conditions hereafter described.

1. Our service
Diplodocs offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...

2. Access rights
The documents available on this site are and will remain properties of their respective owners. Accessing, downloading or storing a document on this site does not give you any right. You certify accessing and storing only documents for which you regularly acquired rights of use, either by owning the item corresponding to the document, or thanks to a right to broadcast the document, given by the copyright owners.

3. Our responsibility
In any way can't Diplodocs be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Diplodocs, for instance, does not offer a translation service.

4. Checking of use
Once downloaded, you must make sure that the Manual matches the Product for which you intend to use it. You agree to remain entirely responsible for the use you do with the instructions contained in the document, no matter whether damages of losses occur following its use.

5. Your commitment
In compensation for using our service, you certify not to harm Diplodocs by any legal action, and to help Diplodocs by promoting the site or uploading new documents. You acknowledge that Diplodocs does not owe you mandatory results or availability.


Diplodocs explicitly forbids the use of its service by anyone who do not agree with all conditions above. By accepting or downloading the Manual TANDBERG 220-420LTO, you agree to have read the disclaimer, to have understood all of it and to be bond by its terms and conditions.

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.

   

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

We hope that this TANDBERG 220-420LTO user guide will be useful to you.

Need help, support, reviews, tips or troubleshooting for your TANDBERG 220-420LTO products ?
Discussion, review, tips, troubleshooting issue, problem : search help on TANDBERG 220-420LTO product forum.




close

Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 400 000 user's guides
Search a brand
Advanced Search




Visit TANDBERG official site

User manual TANDBERG 220-420LTO - QUICK INSTALLATION GUIDE

Diplodocs help download the user guide TANDBERG 220-420LTO - QUICK INSTALLATION GUIDE.

  Download the user manual TANDBERG 220-420LTO     
Download the complete
user guide (205 Ko)
Need help, support, reviews, tips or troubleshooting for your TANDBERG 220-420LTO products ?


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide TANDBERG 220-420LTO - QUICK INSTALLATION GUIDE
Tandberg 220/420LTO Half Height LTO1 and LTO2 Tape Drive Quick Installation Guide Revision 4 ­ February 2006 Mechanical Installation For mechanical mounting specifications, please refer to Figure 1. Allowed mounting position is either horizontal with the indicator LEDs to the right, or vertical with the LEDs up. The drive occupies a half-size 5.25-inch slot with standard holes for mounting screws on both sides of the drive chassis and at the bottom of the drive. Figure 1 Important! Mounting screw requirements · · · · · · Mounting specifications Only M3 (metric) screws must be used for mounting the drive Maximum permitted screw penetration: 2.5 mm Minimum required screw penetration: 2.0 mm Screw torque, mounting screws: 0.5 Nm Screws are supplied with all the Tandberg 220/420LTO drive variants Bags with 4 screws and 4 SCSI ID jumpers are available (Ordering no. 43 32 65) Do not use longer screws or higher screw torque than specified! Figure 2 Allowed mounting orientations 2 SCSI Identification Make sure that the drive unit has the proper SCSI-ID before it is connected to a computer system. Refer to manuals for host computer and application software to obtain the correct ID. For correct mounting of ID-jumpers at the rear of the drive, please refer to Figure 3 and Table 1. External drives have a thumb-wheel switch to set the SCSI-ID (see Figure 6). Power Connector Service Connector SCSI Connector Figure 3 The factory default drive number setting is SCSI ID = 2. If the drive has to be set up with a different unit number, the jumpers (on the Service Connector) have to be connected according to Table 1. Example: SCSI ID = 3 Drive connectors SCSI ID=0 SCSI ID=1 SCSI ID=2 SCSI ID=3 SCSI ID=4 SCSI ID=5 SCSI ID=6 SCSI ID=7 SCSI ID=8 SCSI ID=9 SCSI ID=10 SCSI ID=11 SCSI ID=12 SCSI ID=13 SCSI ID=14 SCSI ID=15 Table 1 Service Connector jumper settings for SCSI ID (Dark = Jumper mounted) 3 SCSI Cable Host SCSI-bus Internal Terminator Connector Last SCSI Device 10 cm Figure 4 SCSI cable (Ordering no. 43 20 51) (Ordering no. 43 20 53) (Ordering no. 43 26 17) (Ordering no. 43 32 64) · Internal SCSI-LVD/SE-cable with 5 connectors · Internal, removable SCSI-LVD/SE-terminator · External, removable SCSI-LVD/SE-terminator · External SCSI 68HD/VHDCI 320MBs-cable Termination The SCSI-bus cable must be terminated in both ends according to SCSI specifications. If the tape drive is the last device on the bus, the bus must be terminated within 10 cm of the tape drive connection. Tandberg 220/420LTO has a combined SCSI-LVD/SE interface embedded. The PC-98 Specification specifies that the termination of the SCSI-bus system is a part of the SCSI-cable and not a part of the SCSI-device. As a result, termination cannot be turned on or off directly on the tape drive itself. For internal devices, a SCSI-cable with an integrated terminator or a separate terminator applied to the end connector of the cable, 10 cm from the last device, must be used. External devices must be terminated with an external terminator on the last device on the SCSI-bus. Software Installation For Software Application support and software drivers, please see www.tandberg.com. Then select SUPPORT and Select Product. For installation of Backup Application software, refer to the software vendor's software application user guide supplied with the software or on the software vendor's web. 4 Front LED Indicators Figure 5 Light Emitting Diodes (LED) Drive State READY LED (Green left) ACTIVITY LED (Green) CLEAN LED (Amber) FAULT LED (Amber right) LED-test. The LEDs are turned ON one-by-one. Power-On Self-Test starts in parallel with the LED-test . Cartridge not loaded. Cartridge loaded, no activity Cartridge loaded, activity Cleaning Cartridge loading or unloading Unrecoverable drive failure Over temperature Media Error (wrong, write protected or harmed media) ON ON ON ON OFF ON ON OFF OFF ON / OFF OFF OFF OFF OFF Flashing Flashing Flashing OFF OFF Flashing ON / OFF ON / OFF ON / OFF ON ON / OFF ON / OFF ON / OFF ON / OFF OFF OFF OFF OFF OFF Flashing ON Flashing Table 2 Front LED behavior during normal operation 5 Media and Capacities To achieve and maintain the maximum quality of your Tandberg Data tape drive, we recommend using Tandberg Data media. Drive Model Tandberg 220LTO Tandberg 420LTO LTO1, 2, 3 LTO Ultrium Generation 2 (Native format) LTO Ultrium Generation 1 (Read/Write compatible) Cleaning Cartridge for LTO1, LTO2 and LTO3 609 m 609 m 200 GByte 100 GByte 43 27 44 43 26 30 43 26 31 Media Name Tape Length 609 m Capacity (Native) 100 GByte Ordering no. 43 26 30 LTO Ultrium Generation 1 (Native format) Table 3 Media alternatives External Tabletop Enclosure ON/OFF Switch Cooling Fan SCSI_ID Switch Power Connector SCSI Interface Connectors Figure 6 External tabletop enclosure, rear side Power Requirements Tandberg 220/420LTO in external tabletop enclosure: AC Input: 100 VAC / 0.6 A or 240 VAC / 0.3 A, 50-60 Hz Tandberg 220/420LTO as standalone: DC Input (typical operation): 5 VDC / 2.1 A, 12 VDC / 0.6 A Heat Dissipation Tandberg 220/420LTO as standalone: Operating: 18 W Sleep mode with cartridge inserted: 9 W 6 Total customer satisfaction is of the utmost importance to Tandberg Data. We guarantee that this product left our premises defect free. If you are not satisfied with the quality of this product, please contact your distributor or the nearest Tandberg Data office to have the problem solved! For more documentation and information, please see our website www.tandberg.com. 7 Tandberg Data International headquarter Tandberg Data ASA, Kjelsåsveien 161, Oslo, P.O. Box 134 Kjelsås, N-0411 Oslo, Norway. Tel: +47 22 18 90 90. Fax: +47 22 18 95 50. www.tandberg.com Worldwide subsidiaries Tandberg Data Corp., 13000 Gregg Street, Poway, CA 92064, U.S.A. Tel: 858-726-1800. Fax: 858-726-1801 Tandberg Data GmbH, Feldstrasse 81, D-44141 Dortmund, Germany. Tel: +49 231 5436 0. Fax: +49 231 5436 111. Tandberg Data S.A.S., 16/18 Ave. Morane-Saulnier, F-78941 Vélizy Cedex, France. Tel: +33 1 39 26 01 01/00800-82632374. Fax: +33 1 34 65 02 89 (for technical support: 00800-07867243). Tandberg Data (Asia) Pte. Ltd, 20 Bendemeer Road, #04-05 Cyberhub, Singapore 339914, Tel: +65 6396 0786. Fax: +65 6396 0787. Tandberg Data (Japan) Inc., Eitaibashi Eco-Piazza Bldg. 8th floor 29-13, Shinkawa 1-chome, Chuo-ku Tokyo 104-033, Japan Tel: +81 3 5566 2871. Fax: +81 3 5566 2875. Tandberg Data Ltd., Bloxham Mill Business Centre, Barford Road, Bloxham, Banbury, Oxfordshire, OX15 4FF, United Kingdom Tel: +44 (0) 8450706916. Specifications subject to change without notice. All trademarks are the property of their respective owners. ©2006 Tandberg Data ASA. All Rights reserved. Part No. 433261-04. February 2006.


TANDBERG 220-420LTO, , Hard Drive, NAS, USB Key & Other external Storage.

Detailed instructions for use are in the User's Guide.

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TANDBERG 220-420LTO.

TANDBERG offer a product for which we do not have the user manual? Let us know what you are looking for: user manual, user guide, instructions, owner's manual, online manual, user's manual, users manual, users guide, owner manual, owners manual, user's guide, handbook, instructions for use, instruction manual, operation manual, operating instructions, installation guide, quick start guide, quikstart guide, getting started, installation instructions, installation guide,mounting instruction, assembly instrucions, fixing instructions, use instruction, schematics, operating manual, feature sheet, data sheet, booklet, service manual, use and care guide, installation manual, installation software, RTFM.

Diplodocs allows you to download user manual TANDBERG 220-420LTO, user guide TANDBERG 220-420LTO, instructions TANDBERG 220-420LTO, owner's manual TANDBERG 220-420LTO, online manual TANDBERG 220-420LTO.


Access web reviews
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.