Detailed instructions for use are in the User's Guide.
Tandberg Data M-Series Installation Guide
Introduction Site Requirements
3 3
Space Requirements ..................................................................................................3 Cooling Considerations ............................................................................................3 Environmental Requirements..................................................................................5 Power and Grounding ..............................................................................................5
Installing a Desktop or Deskside Library
5
Installing a Desktop M1500......................................................................................5 Installing a Deskside M2500 ....................................................................................5
Installing a Rack Mount Library
6
Determining the Position of the Shelves in the Rack ...........................................6 Installing the M1500 Rack Mount Shelves .............................................................8 Installing the M2500 Rack Mount Shelves ...........................................................14 Installing the Library in the Rack..........................................................................28
Installing Drives in the Library
31
Installing Tape Drives in an M1500 ......................................................................31 Installing Tape Drives in an M2500 ......................................................................32
Preparing and Inserting Tape Cartridges
34
Labeling Tape Cartridges .......................................................................................34
Document T6423046-02 A01, February 2004
1
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Setting the Write-Protect Switch............................................................................35 Placing Cartridges in the Library ..........................................................................36
Connecting the Library to AC Power
41
M1500 Power Requirements ..................................................................................41 M2500 Power Requirements ..................................................................................43
Connecting the Library to the Host Computer
45
SCSI Cabling Guidelines.........................................................................................45 Terminator Power....................................................................................................45 SCSI Cabling Diagrams...........................................................................................46
Powering Up the Library Disabling Unused Drive Bays
48 50
2
6207947-04fN 26
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Introduction
This document explains how to install a stand-alone M1500 or M2500. Note: To install an M1500 or M2500 module in a multiple library stack, refer to the Tandberg StackLink Installation Instructions (PN T6423049).
0
Site Requirements
When selecting an installation site for the library, consider the following requirements: · · · · Space Requirements Cooling Considerations Environmental Requirements Power and Grounding
0
Space Requirements 0
Table 1 lists the dimensions of the M1500 and M2500 libraries. Caution: Allow at least 5 inches (12.7 cm) of space behind the library to allow proper ventilation.
Table 1 Library Dimensions
M1500 Height Width Depth 6.9 in. (176 mm) 19 in. (482 mm) 28.6 in. (726 mm)
M2500 23.4 in. (595 mm) 19 in. (482 mm) 28.6 in. (726 mm)
Cooling Considerations
0
Cooling is one of the most important factors to consider when selecting a location for the library. The M1500 and M2500 libraries are force-cooled: air is drawn into the library through vents at the lower edge of the front bezel and
Introduction
3
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
exhausted through vents at the back of the library. To ensure that the library is adequately ventilated: · · Place the library on a hard, level surface, or in a standard 19-inch rack. If the library will be placed in a rack, the rack must be open or ventilated so that the air temperature behind the library at the air outlets is less than 104°F (40°C). Verify that no cables obstruct the vents at the back of the library (see figure 1 and figure 2). Verify that nothing obstructs the vents at the lower edge of the front bezel. Allow at least 5 inches (12.7 cm) of space behind the library or rack. Do not install the library near a heater or radiator which could warm the air drawn into the library.
· · · ·
Figure 1 Vent Locations, M1500
Vents
Figure 2 Vent Locations, M2500
Vents
4
Site Requirements
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Environmental Requirements
0
The installation site (desktop library) or the interior of the rack (rack mount library) must meet the following environmental requirements: · · · Humidity: 20% to 80%, non-condensing Temperature: 50°F to 104°F (10°C to 40°C) Altitude: -100 to +10,000 feet (-30 to +3,000 meters)
Power and Grounding
0
The M1500 and M2500 power supplies accept 88 VAC to 264 VAC input power at 47 Hz to 63 Hz. The library must be connected to a grounded power outlet. If the library is mounted in a rack, the rack must also be grounded.
Installing a Desktop or Deskside Library
0
This section explains how to install a desktop M1500 or a deskside M2500. To install a rack mount library, see Installing a Rack Mount Library. Note: The procedures in this section assume that you have already unpacked the library. If you have not, do so now, referring to the Tandberg M1500 Unpacking Instructions (PN T6421035) or Tandberg M2500 Unpacking Instructions (PN T6423047).
Installing a Desktop M1500 0
To install a desktop M1500: 1 Convert the M1500 to a desktop unit by performing the procedures detailed in the Tandberg M1500 Rack Mount to Desktop Conversion Instructions (PN T6421036). This document is provided with the M1500 Rack Mount to Desktop Conversion Kit. 2 Place the library in the installation location, preferably on a sturdy desk or tabletop. 3 Proceed to Installing Drives in the Library on page 31 to continue the installation procedure.
Installing a Deskside M2500 0
To install a deskside M2500: 1 Convert the M2500 to a deskside unit by performing the procedures detailed in the Tandberg M2500 Rack Mount to Deskside Conversion Instructions (PN T6423048). This document is provided with the M2500 Rack Mount to Deskside Conversion Kit.
Installing a Desktop or Deskside Library 5
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
2 Place the library in the installation location. 3 Proceed to Installing Drives in the Library on page 31 to continue the installation procedure.
Installing a Rack Mount Library
0
This section explains how to install an M1500 or M2500 in a standard 19-inch rack. Note: The procedures in this section assume that you have already unpacked the library. If you have not, do so now, referring to the Tandberg M1500 Unpacking Instructions (PN T6421035) or Tandberg M2500 Unpacking Instructions (PN T6423047).
Determining the Position of the Shelves in the Rack 0
Before starting the rack mount installation: 1 Determine the proper position of the shelves in the rack:
Caution:
Take rack stability into account when determining where to place the library in the rack.
·
The rack is measured in rack mount units. Each unit is called a "U," and is equal to 1.75 inches (44.45 millimeters). When you look at the rack rails you will notice that the holes are divided into groups of three, with each group separated by a slightly smaller space. Each group of three equally spaced holes is one U (see figure 3). An M1500 uses 4U of vertical space. The M1500 rack mount shelves must be installed in a full U position (the bottom of the rack mount shelf must be aligned with the bottom of a U) (see figure 4). An M2500 uses 13.5U of vertical space. The M2500 rack mount shelves can be installed in either a full U or a half U position (the bottom of the rack mount shelf may be aligned with either the bottom or the middle of a U) (see figure 5). The StackLink mounting hardware uses 1U of vertical space at the top of the rack, and either 1U or .5U at the bottom of the rack (see the Tandberg M-Series StackLink Installation Instructions, PN T6423049, for more information).
·
·
·
2 Mark the desired shelf position on the rack rails.
6
Installing a Rack Mount Library
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Figure 3 Example of Full and Half U Mounting Positions
3 equally spaced holes equals 1 U
1U In the half U position, the bottom of the mounting bracket aligns with the center of the middle hole in the corresponding U. This position can be used for M2500 rack mount shelves only.
In the full U position, the bottom of the mounting bracket aligns with the bottom of the corresponding U. This position can be used for either M1500 or M2500 rack mount shelves
Figure 4 M1500 Shelf Mounting Positions
M1500
4U
Shelf mounting position
Installing a Rack Mount Library
7
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Figure 5 M2500 Shelf Mounting Positions
M2500
13.5U
M2500
13.5U
Shelf mounting position (half U position)
Shelf mounting position (full U position)
Installing the M1500 Rack Mount Shelves 0
This section explains how to install the M1500 rack mount shelves. Note: To install rack mount shelves for an M2500, see Installing the M2500 Rack Mount Shelves on page 14.
Checking the Contents of the Rack Mount Kit Table 2 lists the contents of the M1500 Universal Rack Mount Kit.
0
Table 2 Contents, M1500 Universal Rack Mount Kit
Part No. 213467 213468 213469 213471 213472
Description Shelf clamp Insert (9 sq) Insert (7 sq) Insert (M6) Insert (M5 or 12-24UNC)
Qty. 4 8 8 8 8
8
Installing a Rack Mount Library
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Part No. 213473 213474 213476 213477 213478 213479 YS40403 YS40403 YS41720 YS41998 YS42008 YS42011 YS42038 YS42042 YS42043 YS42044
Description Insert (10-32UNF) Insert (1/4" dia) Universal shelf, right Universal shelf, left Shelf extender #1 Shelf extender #2 Plain washer M5 Plain washer M5 Button head socket screw 10-24 UNC x 0.5 ins Nut, M5 full M6 cage nut Button head socket screw M6 x 12 Countersink hex socket screw M4 X 10 LG Button head socket screw M5 x 12 Button head socket screw 10-32 UNC x 0.5 ins M5 spire nut
Qty. 8 8 1 1 1 1 4 2 2 4 2 2 4 2 2 2
Verifying That You Have the Required Tools The following tools are required to install the rack mount kit: · · · · 8 mm open end wrench 2.5 mm socket driver (preferably ball headed) Flat blade screwdriver Tape measure
0
Assembling the Rack Mount Shelves 1 Measure the distance between the inside surfaces of the front and rear rack rails, then find the corresponding rack depth in table 3. 2 Assemble the left shelf: a b Refer to the Left Shelf/Shelf Extender column of table 3 to determine which shelf extender to combine with the left universal shelf.
0
Insert the posts on the left universal shelf into the shelf extender slots identified in the Left Shelf/Slots column of table 3. The slots in the shelf extenders are identified as shown in figure 6.
Installing a Rack Mount Library 9
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
c
Use the M5 nuts (PN YS41998) and M5 washers (PN YS40403) provided in the rack mount kit to fasten the left shelf and shelf extender together (see figure 7). Note: Tighten the nuts to finger-tightness only; you need to be able to retract and extend the assembled shelves slightly.
3 Assemble the right shelf in the same manner, referring to the Right Shelf column of table 3.
Table 3 Shelf Assembly Matrix
Left Shelf Rack Depth (between flanges) 24.50 in. - 26.75 in. (620 mm - 680 mm) 26.75 in. - 29.125 in. (680 mm - 740 mm) 29.125 in. - 31.50 in. (740 mm - 800 mm) 31.50 in. - 33.875 in (800 mm - 860 mm) 33.875 in. - 36.25 in. (860 mm - 920 mm) Shelf Extender #2 #1 #2 #1 #2
Right Shelf Shelf Extender #1 #2 #1 #2 #1
Slots A&B B&C B&C C&D C&D
Slots A&B A&B B&C B&C C&D
Figure 6 Identifying the Shelf Extender Slots
A B C D
10
Installing a Rack Mount Library
Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004
Figure 7 Attaching the Shelves to the Extenders
Extender
Shelf
Installing the Rack Mount Shelves To install the rack mount shelves: 1 From the six sizes of inserts provided in the rack mount kit, select the insert type that best fits the holes in the rack rails. The insert part numbers are: · · · · · · 213468 (for rails with 9 mm square holes) 213469 (for ra ...