Detailed instructions for use are in the User's Guide.
*
T-TOUCH EXPERT User's Manual
27.12.07
Acknowledgements
We would like to thank you for choosing a TISSOT watch, a Swiss brand among the most highly renowned in the world. Your T-TOUCH watch has the most recent technical innovations. It gives you a constant analogue time display and a variety of digital displays. In addition, the following functions can be accessed simply by touching the glass: Weather, Altimeter, Chronograph, Compass, Alarm and Thermometer.
w ww.tissot.ch
1/13
141_ E N
T-TOUCH EXPERT
*
FUNCTIONS
2nd function 1st function
hPa
1st function
2nd function
1015
A
hPa
R
1020 1025
4478m
m
+
27°
NEW-YORK LONDON
T
OPT
december
27
T2
27.12. 07
2
ACTIVATE TOUCHSENSITIVE GLASS
ACTIVATE LIGHT
N W S E
N
45°
CAL
A
Water resistance: 10 atm / 100 m / 330 ft
Time T Time T2 Alarm 2
T2
AR
R Relative pressure, Active altitude difference meter A Absolute pressure, Azimuth
Active touch-sensitive glass
Activate touch-sensitive glass / Activate light
CHRONO Â Chronograph
9 9 10 10 11 12 12 12
december
27
CENTRE Â Date
3
N
CHRONO Â Timer
LONDON
T
CENTRE Â Time 1
3 4 4
W S
E
COMPASS Â Compass
N
A
NEW-YORK
T2
CENTRE Â Time 2
45°
COMPASS Â Azimuth
CENTRE Â Options
OPT
hPa
COMPASS Â Calibration
CAL
1015 1020 1025
METEO Â Weather, relative pressure
R
6 6 7 8
ALARM Â Alarm 1
METEO Â Weather, absolute pressure
A
hPa
2
ALARM Â Alarm 2
4478m
ALTIMETER Â Altimeter
27°
THERMO Â Thermometer
m
ALTIMETER Â Altitude difference meter
www.tissot.ch
2/13
141_ E N
T-TOUCH EXPERT
*
GENERAL USER INFORMATION
Activating the touch-sensitive glass Activating the light Setting mode
2 sec. 1 sec.
27.12.07 27.12.07
Display mode
Activate the glass
2 sec.
27.12.07 27.12.07
27.12.07
When the glass is activated, the symbol will flash on the digital display. If the glass is not touched, it will automatically deactivate after 15 seconds. Exception: In compass and altitude difference meter mode, the glass will deactivate after 30 seconds.
The display light will stay on for 5 seconds.
27.12.07
27.12.07
Date display = Default display
Select a function
or
27.12.07 27.12.07
10:10 10
T
Time 1 display: T
12:10 10
T2
Time 2 display: T2
: move display and/or hand
position forward
Touch one of the 7 touch-sensitive areas of the glass to activate the corresponding function. : move display and/or hand
OPt.
Options Display Return to Date display
position backward If no manipulation for 10 seconds, the setting mode is deactivated.
LONDON
T
NEW-YORK
T2
SETTING > TIMES T & T2
Pressing and holding or will move the hands forward or backward. After a full revolution, the minutes hand will stop and the hour hand advances/reverses in steps of one hour. Time T2 is set in steps of 15 minutes. 2 sec. 1 sec.
or
10:10 07
T
27.12.07
10:10 00
T
11:32 27
11:32 00
T
11:32 27
T
a)
b)
27.12.07
Activate glass
10;10 00
T
10:10 00
T
11:32 27
T
11:32 00
T
11:32 27
T
Time T or T2 display (example: T)
Setting mode
: forward 1 min. : back 1 min. (hands and display)
Validate setting a) The seconds restart at zero b) The seconds continue
december
27
SETTING > DATE
The calendar is perpetual, i.e. the number of days per month is predefined. In continuous setting, the days scroll past slowly at first, and then quicker. After a full month, the calendar scrolls in months, and then likewise in years. 2 sec. 1 sec.
27.12.07 27.12.07 27.12.07 28.12.07
or
28.12.07
or
28.12.07
27.12.07
Activate glass
27.12.07
Date display
27.12.07
Setting mode
28.12.07
: forward one day : back one day
28.12.07
Validate setting
www.tissot.ch
3/13
141_ E N
T-TOUCH EXPERT
*
READING > OPTIONS
OPT
1 sec.
27.12.07 OPt. 24h CM
0
bEEP on
SLEEP
27.12.07
Activate glass
OPt.
Options display (see page 3)
24h CM
0
bEEP on
Beep display
SLEEP
Automatic switch to standby mode after 5 seconds Beep every second
Switch to sub-menus: Units display
noSEt
24h CM
0
27.12.07
noSEt
Climate zone display
24h CM
0
27.12.07
At any time: exit sub-menu  back to date display
Back to units display
OPT
SETTING > UNITS
2 sec. or
24h CM
0
24h CM
0
24h CM
0
24h CM
0
24h CM
0
24h CM
0
24h CM
0
24h CM
0
24h CM
0
12h CM
0
24h CM 24h FFT
0 0
24h CM
0
Units display
Setting mode
Select mode 12/24 hours  in 12 hour mode, the letter A (AM) or P (PM) appears between minutes and seconds when setting the time
Select Mode "º C / m" or "º F / ft"
Validate setting. Selecting 12 hour mode displays the date in the format 12.27.2007 (month, day, year), and 24 hour mode in the format 27.12.2007 (day, month, year).
OPT
SETTING > BEEP
2 sec.
bEEP of
or
bEEP of
or
bEEP of
bEEP on
bEEP on
Deactivating the sound silences adjustment beeps but not the alarms.
bEEP on
Beep display
bEEP on
Setting mode
bEEP on bEEP of
Activated = on , Deactivated = off
bEEP of
Validate setting
www.tissot.ch
4/13
141_ E N
T-TOUCH EXPERT
*
OPT
SETTING > STANDBY
Standby mode is a battery economy mode. All the functions are deactivated, with only the time & date counters updated. This mode economises the battery when the watch is not being worn.
27.12.07
27.12.07
SLEEP
Automatic switch to standby mode after 10 seconds Beep every second
a) The watch is in standby
Back to time & date mode
or
SLEEP 27.12.07
SLEEP
b) / : stop the count, the watch does not switch to standby mode
27.12.07
Back to time & date mode
SETTING > HEMISPHERE AND CLIMATE ZONE
OPT
To get the best from the altimeter function, it is possible to adjust the hemisphere and climate zone to your geographic location. Select your climate zone according to the simplified Koeppen climate classification (see illustration on right). If the watch is not set ("No Set"), the standard atmosphere model is used: set temperature at sea level = 15°C, mean pressure at sea level: 1013.25 hPa
N S
Polar
Temperate
Arid
Tropical
Mediterranean
2 sec. or
noSEt noSEt North T North M North T North T
noSEt
Climate zone display
noSEt
Setting mode
North T South T noSEt
Select hemisphere: North = North, South = South not set = not set
North M North A Northtr North P
Set the local climate: T = temperate; M = Mediterranean; A = arid; tr = tropical; P = polar
North T
Validate setting
www.tissot.ch
5/13
141_ E N
T-TOUCH EXPERT
*
SETTING > SYNCHRONISATION
OPT
The watch needs to be synchronised if the watch hands do not display the same time as the digital display, or if they are not correctly superimposed when accessing the functions.
10:10 00
T
10:10 00
T
The watch is desynchronised when its electric motor's mechanism is disturbed due to heavy impacts for example. N.B.: The glass must be active to access the synchronisation mode.
Synchronised
Desynchronised
or 5 sec.
24h 0 CM SYNCHRO SYNCHRO
or or
or
SYNCHRO SYNCHRO SYNCHRO
10:10 00
T
10:10
T
24h CM
0
SYNCHRO
Synchronisation setting mode The hands should be perfectly superimposed in the 12 o'clock position Position the hour hand at 12 o'clock
SYNCHRO
Validate setting Position the minutes hand at 12 o'clock
10:10 00
T
Units display
Validate setting Return to Time T mode
hPa
1015 1020 1025
R
A
hPa
WEATHER
In weather mode, the hands are superimposed to indicate the weather trend.
1 sec.
27.12.07 1005hPA
R
995hPA
A
27.12.07
Activate glass
hPa
1005hPA
R
995hPA
A
Relative pressure display in hPa
Absolute pressure display in hPa
1015 1020 1025
SETTING > RELATIVE PRESSURE PRESETTING
Setting this pressure changes the altitude displayed. The possible relative pressure is deliberately limited between 950 hPa and 1100 hPa.
R
2 sec.
or
1005hPA
R
or
1004hPA
R
1004hPA
R
1004hPA
R
1005hPA
R
1004hPA
R
1004hPA
R
Setting mode
: up one hectopascal : down one hectopascal
Validate setting
www.tissot.ch
6/13
141_ E N
T-TOUCH EXPERT
*
hPa
1015 1020 1025
R
A
hPa
GLOSSARY > WEATHER
Variable
Storm
Sunny
Description of function In weather mode, the hands are superimposed to indicate the weather trend.
1004hPA
A
Explanations Weather changes are related to variations in atmospheric pressure. When atmospheric pressure increases the sky clears. The area is then referred to as a "high pressure" area or "anticyclone" (A). When atmospheric pressure decreases the sky clouds over. The area is then referred to as a "low pressure" area or "depression" (D). The T-TOUCH measures these pressure variations and indicates the weather trend with the hands, which can adopt the following 7 positions according to the weather developments: Big pressure drop, rapid deterioration Moderate pressure drop, probable deterioration - 2': Small pressure drop, probable slight deterioration 12 o'clock: No notable weather change + 2': Slight pressure rise, probable slight improvement + 4': Moderate pressure rise, probable improvement + 6': Big pressure rise, rapid improvement - 6': - 4':
The T-TOUCH program takes account of atmospheric pressure variation over the last 6 hours to calculate the trend to indicate. Furthermore, the pressure variation caused by a rapid change in altitude is detected by the watch and compensated for automatically. So it only has a minimal impact on the barometric trend.
A The T-TOUCH digital display indicates the 1020 1015 absolute and relative atmospheric pressure 1010 values in hectoPascals [hPa]. Absolute atmospheric pressure is the actual pressure D 990 at the time and place of measurement, and 995 1000 cannot be altered. Relative pressure is a 15 10 1 0 02 0 10 1005 1A * value relative to sea level, based on local absolute atmospheric pressure . Barometers and weather charts show relative pressure values. The relative pressure value depends on the climate zone set, and can be preset on the watch. The relative pressure presetting is in line with the altitude.
6
42
12
24
6
Characteristics of function Measurement range: absolute pressure: 300 hPa to 1100 hPa relative pressure: 950 hPa to 1100 hPa Accuracy: absolute pressure: ± 3 hPa relative pressure: varies with altimeter Resolution: 1 hPa Unit conversion: 1 hectoPascal [hPa] = 1 millibar [mb]
4478m
m
ALTIMETER
The altitude is displayed on the digital screen for 10 hours continuously. After 10 hours, the altimeter mode is deactivated, and the date is displayed.
1 sec.
27.12.07 792M
03:18h55
27.12.07
Activate glass
792M 2599FT
Altitude display
03:18h55
Altitude difference display
4478m
m
SETTING > ALTITUDE PRESETTING
2 sec.
or
792M 792M 795M 795M
or
795M
792M
Altitude display
792M
Setting mode
795M
: up 1 m or 3 ft : down 1 m or 3 ft
795M
Validate setting
www.tissot.ch
7/13
10
141_ E N
10
T-TOUCH EXPERT
*
m
ALTIMETER > ALTITUDE DIFFERENCE
Sequentially every 2 seconds
2 sec. 2 sec.
03:18h55
03:18h55
1188A
Total cumulative gain in altitude during elapsed time
18A5
Mean vertical speed of ascent (metres/minute or feet/minute)
Elapsed time or stopped time
2 sec. 2 sec.
03:18h55
Altitude difference display
3192d
24d5
Mean vertical speed of descent (metres/minute or feet/minute)
2 sec.
03:18h55
Back: Elapsed time or stopped time
Total cumulative loss in altitude during elapsed time
00:00h00
R
03:18h55
R
00:00h00
2 sec.
rUn 00:00h00
R
STOP 03:18h55
R
rESET 00:00h00
Reset Altitude difference meter
Start Altitude difference meter
Stop Altitude difference meter
4478m
m
GLOSSARY > ALTIMETER
We advise you to stop the altitude difference meter during rest times and then restart it, in order to obtain more accurate results.
792M
R
Description of function In altimeter mode, your T-TOUCH becomes a barometric altimeter, displaying the altitude relative to mean sea level.
...