9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your TRANSTEL GROUP LINE SENSOR VERSION 7.1 FOR ML500 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

User manual TRANSTEL GROUP LINE SENSOR VERSION 7.1 FOR ML500

Diplodocs help download the user guide TRANSTEL GROUP LINE SENSOR VERSION 7.1 FOR ML500 .

Download the complete user guide (10 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide TRANSTEL GROUP LINE SENSOR VERSION 7.1 FOR ML500

Detailed instructions for use are in the User's Guide.

Version 7.1 LS-U Line Sensor for the TransTel ML500 System The TransTel Version 7.1 LS-U Line Sensor offers several unique features when a Telco line is connected to the RJ11 Jack marked TELCO at the rear panel of the ML500 chassis. · · · · · · Automatic switching to cellular transmission within 5 to10 seconds if the telco line has been cut or tip-ring voltage is no longer present. Automatic switching to cellular transmission within 0.25 seconds if no telco dial tone is present when an off-hook condition occurs. Depending on fault condition, dry contact closure (rear panel of chassis) for an indefinite number of hours. The dry contacts can be used to activate an alarm (to be provided by user). Automatic switching to telco line when the fault condition has been corrected and peripheral equipment is on-hook. This means that a cellular call in progress will not be interrupted. In telco mode of operation, an incoming cellular call will ring analog peripheral equipment (telephones, modems) connected to the PBX/PHONE RJ11 jack at the rear panel of the chassis. In the telco mode of operation, it is possible to access the cellular mode by depressing the CELLULAR MODE button on the front panel of the transceiver module. The Line Sensor module consists of a separate board. It can be accessed by extracting the transceiver module. However, prior to removal of the transceiver module, turn off the power supply and disconnect antenna and telephone cabling at the rear of the of the chassis. In addition, two captive black retaining screws (one in the extraction handle and one at the top of the module front panel) must be loosened. Exercise great care when extracting a transceiver module and avoid any damage to the components of the module. The Line Sensor board is located at the rear section of the module. Two switches (SW1 and SW2 on the left upper edge of the Line Sensor board) control settings for closure of the dry contacts on the rear panel of the chassis. Switch settings from 0 through 9 result in the following actions: SWITCH SETTINGS SW2 (left switch) Duration in Increments of 0 or 2n-1 Hours 0 n=1 through 8: 1, 2, 4, 8, 16, 32, 64, or 128 hrs. n=9: indefinite number of hours or until ALARM RESET is pressed; (factory default). SW1 (right switch) Alarm Activation after n Minutes Any setting 0 (factory default) Switch settings 1 to 9 (n=1, 2, 4 ,8 ,16 , 32, 64 ,128 , or 255 minutes delay) ACTION IF TELCO LINE VOLTAGE IS LOST ACTION IF TELCO DIAL TONE IS LOST No alarm contact closure Red ALARM LED on immediately for duration set with SW2. Alarm contact closure delayed by SW1 setting; alarm contacts on for number of hours set by SW2. No alarm contact closure Red ALARM LED on immediately for duration set with SW2. Alarm contact closure delayed by SW1 setting; alarm contacts on for number of hours set by SW2. Use a fine-blade screw driver to change any of the settings of switches SW1 and SW2. Reinsert the transceiver module into the chassis, tighten the captive screws on the front panel of the module and connect antenna and telephone cabling at the rear of the chassis. Note: If a transceiver module is equipped with a SIGNAL LED, the following conditions apply: 1. The dry contacts close (red ALARM LED on) when the cellular signal is lost regardless of the setting of SW1 and SW2 or the mode of operation (telco or cellular). The contacts remain closed until the fault condition is corrected. The contacts open automatically (red ALARM LED off) when signal is again acquired or the fault condition has been corrected. 2. All rights reserved. Changes without prior notice. TransTel Group, Inc. 104101 Page 1 of 1 ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.