Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit UNIDEN official site

User manual UNIDEN UBC3500XLT

Diplodocs help download the user guide UNIDEN UBC3500XLT.



Download the user manual UNIDEN UBC3500XLT  
Download the complete
user guide (794 Ko)
Need help, support, reviews, tips or troubleshooting for your UNIDEN UBC3500XLT products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide UNIDEN UBC3500XLT

Detailed instructions for use are in the User's Guide.

UBC3500XLT OWNER'S MANUAL OWNER'S MANUAL Precautions Before you use Precautionsthis scanner, please read and observe the following. EARPHONE WARNING! Be sure to use only a monaural earphone with this scanner. You can also use an optional 32 stereo headset. Use of an incorrect earphone or stereo headset might be potentially hazardous to your hearing. The output of the phone jack is monaural, but you will hear it in both headphones of a stereo headset. Set the volume to a comfortable audio level coming from the speaker before plugging in the monaural earphone or a stereo headset of the proper impedance (32 ). Otherwise, you might experience some discomfort or possible hearing damage if the volume suddenly becomes too loud because of the volume control or squelch control setting. This might be particularly true of the type of earphone that is placed in the ear canal. WARNING! Uniden does not represent this unit to be waterproof. To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture. Uniden® and Bearcat® are registered trademarks of Uniden America Corporation. Close CallTM are proprietary trademarks of Uniden America Corporation. Other trademarks used throughout this manual are the property of their respective holders. Important: If you use the supplied AC adapter to power the scanner but have not installed batteries in the scanner, never turn the scanner off by disconnecting the AC adapter or unplugging it from the AC outlet. This might corrupt the scanner's memory. Always use to turn the scanner off before disconnecting AC power. 2 Contents Introduction ................................................................................................. 6 Contents Feature Highlights....................................................................................... 8 About This Manual ................................................................................... 12 Using the Multifunction Scroll Control ................................................... 12 Entering Text ......................................................................................... 12 How the Scanner's Controls Are Represented in This Manual ............. 13 Understanding Scanning.......................................................................... 15 Understanding the Scanner's Memory ..................................................... 15 What is Scanning? ................................................................................... 15 What is Searching? .................................................................................. 15 What is CTCSS/DCS?.............................................................................. 16 Conventional Scanning ............................................................................ 18 Simplex Operation................................................................................. 18 Repeater Operation............................................................................... 19 Where To Get More Information............................................................... 19 Information On The Internet .................................................................. 19 Included With Your Scanner .................................................................... 20 Setting Up Your Scanner .......................................................................... 20 Using Internal Batteries ............................................................................ 21 Using Rechargeable Batteries.................................................................. 22 Removing the Display Sticker .................................................................. 23 Using AC Power ....................................................................................... 23 Connecting the Antenna........................................................................... 24 Connecting an Optional Antenna .......................................................... 24 Connecting an Earphone/Headphone ...................................................... 24 Connecting an Extension Speaker ........................................................... 24 Attaching the Belt Clip .............................................................................. 25 Attaching the Wrist Strap.......................................................................... 25 A Look At The Keypad ............................................................................. 25 A Look At The Display.............................................................................. 28 Using Menu .............................................................................................. 30 Using Func ............................................................................................... 30 Basic Operation......................................................................................... 31 Turning On the Scanner and Setting the Squelch.................................... 31 Scanning Systems.................................................................................... 32 Selecting Systems to Scan....................................................................... 32 Selecting System Channel Groups .......................................................... 33 Locking/Unlocking Systems ..................................................................... 33 Locking/Unlocking Channels .................................................................... 34 Temporarily Holding On a System ........................................................... 34 Holding On a Channel .............................................................................. 34 Quick-Storing Channels ........................................................................... 34 Quickly Recalling Channels...................................................................... 35 Toggling Channel Alpha Tags .................................................................. 35 Using the Menu.......................................................................................... 36 Settings ...................................................................................................... 38 Displaying System Information................................................................. 38 Viewing Memory Used .......................................................................... 38 Viewing the Firmware Version............................................................... 38 Adjusting the Key Beep ............................................................................ 38 Locking/Unlocking the Keypad and Scroll ................................................ 38 Turning Power Save On or Off ................................................................. 39 Priority Scan ............................................................................................. 39 Using the Backlight................................................................................... 39 Setting the Audio AGC ............................................................................. 40 Adjusting the Display Contrast ................................................................. 40 Initializing the Scanner's Memory............................................................. 40 Connecting Your Scanner to a Personal Computer ................................. 40 Contents 3 Using the Cloning Options ....................................................................... 41 Wired Cloning ....................................................................................... 42 Programming Radio Systems.................................................................. Programming Conventional Systems ...................................................... Entering/Editing Conventional Channel Groups ................................... Entering/Editing Conventional Channels .............................................. Programming/Editing Optional Settings ................................................ System-Level Settings ............................................................................. Editing the System Name ..................................................................... Editing the System Quick Key .............................................................. Setting System Lockout ........................................................................ Setting the System Hold Time .............................................................. Setting the Channel Delay Time ........................................................... Setting the Data Skip ............................................................................ Deleting Systems .................................................................................. Copying Systems .................................................................................. Group-Level Settings ............................................................................... Entering/Editing the Group Name......................................................... Setting the Group Quick Key ................................................................ Setting Group Lockout .......................................................................... Deleting Groups .................................................................................... Channel-Level Settings............................................................................ Editing the Channel Name .................................................................... Editing Frequencies .............................................................................. Setting Channel Priority ........................................................................ Setting Channel Alert ............................................................................ Setting CTCSS/DCS ............................................................................. Setting the Channel Frequency Modulation.......................................... Setting Channel Attenuation ................................................................. Setting Channel Lockout....................................................................... Deleting Channels ................................................................................ Copying/Pasting Channels ................................................................... Searching and Storing ............................................................................. Service Search ........................................................................................ Changing the step of Air Band................................................................. Quick Search ........................................................................................... Custom Search ........................................................................................ Editing a Custom Search Range .......................................................... Editing a Service Search ...................................................................... Auto Search and Store ............................................................................ Selecting a System ............................................................................... 43 43 44 45 46 46 46 46 47 47 48 48 49 49 49 49 50 51 51 51 51 52 53 53 54 55 56 56 57 57 59 59 59 59 60 61 62 63 64 Using the Close Call Feature ................................................................... 65 Setting Close Call Options....................................................................... 66 Close Call Hits ......................................................................................... 69 Search and Close Call Options ............................................................... Managing Locked-Out Frequencies......................................................... Unlocking All Frequencies .................................................................... Reviewing Locked Out Frequencies ..................................................... Searching for Subaudible Tones ............................................................. Screening Out Broadcast Sources .......................................................... Setting the Maximum Auto Store Value................................................... Setting the Modulation Type .................................................................... Setting Attenuation .................................................................................. Setting Data Skip ..................................................................................... Setting the Delay Time ............................................................................ Setting the Search Frequency Step......................................................... Setting Air Band Step .............................................................................. 70 70 70 70 71 71 72 72 73 73 74 74 75 Using Tone-Out......................................................................................... 76 Fire Tone-Out Introduction....................................................................... 76 4 Setting Tone-Out Standby .................................................................... 76 Setting Up Tone-Out............................................................................. 76 Care and Maintenance.............................................................................. General Use............................................................................................. Location ................................................................................................... Cleaning................................................................................................... Repairs .................................................................................................... Birdies...................................................................................................... 79 79 79 79 79 80 Troubleshooting ....................................................................................... 81 Specifications ........................................................................................... 83 Optional Accessories ............................................................................... 85 Appendix ................................................................................................... 86 Planning..................................................................................................... Collecting Information .............................................................................. Filling Out The Conventional System Worksheet .................................... System Name and Quick Key............................................................... Group Name and Quick Key................................................................. Frequency-Alpha Tag-Priority-CTCSS/DCS......................................... 89 89 90 90 90 91 Conventional System Worksheet............................................................ 92 Declaration of Conformiry ....................................................................... 93 Contents 5 Introduction Introduction Your Bearcat UBC3500XLT scanning receiver is a state-ofthe-art scanner radio with extended frequency. You can store frequencies such as police, fire/emergency, marine, air, amateur, and other communications into the scanner. You can carry it with you wherever you go. You can use the scanner's scroll control to quickly select channels and frequencies, and you can automatically program channels in a system using the AutoStore feature. Use your scanner to monitor: · Police and fire departments (including rescue and paramedics) · Business/Industrial radio and utilities · Marine and amateur (ham radio) bands · Air band · Railroad The chart below identifies the scanner band numbers, the frequency range, the modulation mode and the default step size settings. To change the band plan: 1. Maker sure the power is turned off. 2. While holding down 1, 2 or 3 (corresponding number of the band plan), turn on the scanner. Band Plan 1 Frequency (MHz) Lower Edge 25.0000 30.0000 80.0000 83.0000 87.3000 108.0000 108.0000 137.0000 138.0000 158.0000 160.6000 162.6000 174.0000 216.0000 225.0000 400.0000 406.0000 440.0000 466.0000 470.0000 806.0000 1240.0000 Upper Edge 29.9950 79.9875 82.9900 87.2875 107.9500 136.9875 136.9916 137.9950 157.9875 160.5900 162.5875 173.9900 215.9500 224.9950 399.9500 405.9875 439.9937 465.9950 469.9900 512.0000 960.0000 1300.0000 Modulation FM FM FM FM FMB AM FM FM FM FM FM WFM FM AM FM FM FM FM FM FM FM Step (kHz) 5 12.5 10 12.5 50 12.5 / 8.33 selectable 5 12.5 10 12.5 10 50 5 50 12.5 6.25 5 10 6.25 12.5 12.5 6 Band Plan 2 Frequency (MHz) Lower Edge 25.0000 50.0000 84.0150 87.3000 108.0000 108.0000 137.0000 144.0000 146.0000 156.0000 157.4375 160.6000 162.0300 174.0000 216.0000 225.0000 400.0000 406.0000 440.0000 450.0000 470.0000 806.0000 1240.0000 Upper Edge 49.9950 84.0100 87.2950 107.9500 136.9875 136.9916 143.9950 145.9875 155.9900 157.4250 160.5875 162.0250 173.9900 215.9500 224.9950 399.9500 405.9875 439.9937 449.9937 469.9900 512.0000 960.0000 1300.0000 Modulation FM FM FM FMB AM FM FM FM FM FM FM FM WFM FM AM FM FM FM FM FM FM FM Step (kHz) 5 5 20.00 with 15kHz Offset 50 12.5 / 8.33 selectable 5 12.5 10 12.5 12.5 12.5 10 50 5 50 12.5 6.25 6.25 10 6.25 12.5 12.5 Band Plan 3 Frequency (MHz) Lower Edge 25.0000 30.0000 80.0000 83.0000 87.3000 108.0000 108.0000 137.0000 138.0000 158.0000 160.6000 162.6000 174.0000 216.0000 225.0000 400.0000 406.0000 440.0000 466.0000 470.0000 806.0000 1240.0000 Upper Edge 29.9950 79.9937 82.9937 87.2937 107.9500 136.9875 136.9916 137.9950 157.9937 160.5937 162.5937 173.9937 215.9500 224.9950 399.9500 405.9875 439.9937 465.9937 469.9937 512.0000 960.0000 1300.0000 Modulation FM FM FM FM FMB AM FM FM FM FM FM WFM FM AM FM FM FM FM FM FM FM Step (kHz) 5 6.25 6.25 6.25 50 12.5 / 8.33 selectable 5 6.25 6.25 6.25 6.25 50 5 50 12.5 6.25 6.25 6.25 6.25 12.5 12.5 Introduction 7 Feature Highlights Feature Highlights General 2500 Dynamic Channels - Your scanner stores channels more efficiently than conventional scanners, letting you store and quickly tune greater numbers of interesting frequencies. Close CallTM RF Capture Technology - You can set the scanner so it detects and provides information about nearby radio transmissions. See "Using the Close Call Feature" on Page 65 for more information. Dynamically Allocated Channel Memory - Your scanner's memory is organized so that it more closely matches how radio systems actually work, making it easier to program and use your scanner and determine how much memory you have used and how much you have left. Quick Keys ­ You can set the scanner so you can quickly select systems and groups by using the keypad. This makes it easy to listen to or quickly lock out those systems or groups you don't want to scan. Air Service Search - frequencies are preset to make it easy to search and scan for the transmissions. Lockout ­ You can lock out any system, group, frequency, or channel while scanning or searching. If you lock out a system or group, any channels belonging to that system or group are also locked out. You can lock out up to 200 frequencies and review all locked-out frequencies. The scanner skips locked-out frequencies while using the Close Call feature or while searching. CTCSS and DCS Squelch Modes ­ prevent interference from stations not using the mode you select. Fire Tone-Out Standby ­ Lets you set the scanner to alert you if a two-tone sequential page is transmitted. You can set up to 10 settings (transmit frequency, tone frequencies) then select one for standby monitoring. 8 Broadcast Screen ­ Sets the scanner so it ignores Close CallTM or search hits on known broadcast frequencies. Custom Screen ­ Lets you input up to 10 frequency ranges that the scanner will ignore during Close CallTM or search operation. Dropout Delay ­ You can set whether the scanner pauses at the end of a transmission to wait for a reply. You can set the delay time for each system you scan, and while searching and using the Close CallTM feature. Attenuator ­ You can set the scanner's attenuator to reduce the input strength of strong signals by about 25 dB. Repeater Reverse ­ You can set the scanner so it switches to the input frequency on a conventional repeater system. Channel Alert ­ You can set the scanner so it alerts you when there is activity on any channel you specify. Memory Check ­ Lets you see at a glance how much total memory is left. Scan and Search Operation ­ Lets you include service search or custom search ranges during normal scan operation. Custom Alerts ­ For each alert in the scanner (such as channel alert, Close Call alert, emergency alert), you can select from 9 different tone patterns and also set the alert volume level independently from the main volume level. Automatic Channel Step ­ Accepts frequencies on any valid channel step, even if it does not fall within the band plan's default step. Frequency Step ­ Lets you select a frequency step (5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHz) for manual mode and chain search mode. The scanner's auto step feature lets you set the scanner so it automatically chooses the correct step. Feature Highlights 9 Quick Recall ­ Lets you quickly select a specific channel by choosing the system, group, and channel. Scan/Search Delay ­ You can set the scanner so it remains on a frequency up to 5 seconds after the last transmission to wait for a possible reply. Text Tagging ­ You can name each system, group, channel and custom search range using up to 16 characters per name. Unique Data Skip ­ Allows your scanner to skip unwanted data transmissions and reduces birdies. Duplicate Frequency Alert ­ Alerts you if you try to enter a duplicate name or frequency already stored in a system. Memory Backup ­ If power is lost or disconnected, the scanner retains the frequencies you programmed in its memory. Note: The scanner's frequency coverage is not continuous. Search Air Service Search ­ Lets you search the scanner's preprogrammed frequencies. Custom Search ­ Lets you program up to 10 custom search ranges. You can search any of these ranges simultaneously. CTCSS/DCS Search ­ Lets the scanner search for CTCSS or DCS tones. You can identify up to 50 CTCSS tones and 104 DCS tones. Quick Search ­ Lets you search from the currently-tuned frequency if you are searching a conventional system. Auto Store Frequency AutoStore ­ Automatically stores all active frequencies into the selected conventional system. 10 Priority Priority Scan ­ Priority channels let you keep track of activity on your most important channel(s) while monitoring other channels for transmissions. Priority Plus ­ You can set the scanner so it scans only the priority channels Backlight and Power Display and Keypad Backlight ­ Makes the display and keypad easy to see in dim light. You can adjust the back light so it turns on when you press a key, when squelch breaks during a transmission, or manually. Low Battery Alert ­ The scanner alerts you if the batteries need to be recharged or replaced. Battery Save ­ You can set the scanner so it reduces the amount of power it needs if there are no transmissions. Key Controls Key Lock ­ You can deactivate the scanner's keys to help prevent accidentally changing the scanner's programming. PC Control and Cloning PC Control ­ You can transfer programming data to and from your scanner and your personal computer, and control the scanner using a computer and optional software available at http://www.racescanner.eu. This helps you find frequencies listed on the Internet and load them into the scanner. Clone Mode ­ You can clone all programmed data, including the contents of the scanner's memory, menu settings, and other parameters from one UBC3500XLT scanner to another UBC3500XLT scanner. Feature Highlights 11 About This Manual The screen displays used in this manual are representations of what might appear when you use your scanner. Since what you see depends on the frequencies for your area and the settings you select, you might notice some differences between what is in this manual and what appears on your scanner. Using the Multifunction Scroll Control The scroll control on top of the UBC3500XLT lets you easily control channel selection, volume, and squelch, and how information appears on the display. To adjust menu settings, change channels in Hold mode, and resume scanning: Simply rotate the scroll control. To change the scanner's volume: Briefly press the scroll control once, then rotate it. VOLUME LEVEL and the current volume level appear on the display. To adjust the squelch: While holding down Func on the left side of the scanner, briefly press the scroll control once then rotate it. SQUELCH LEVEL and the current squelch level appear on the display. Entering Text To enter a letter, turn the scroll control until the character you want appears, To enter a number, press a number key. To enter a decimal point, press . To move the cursor to the left, press /4. To move the cursor to the right, press 6/ . To clear a character, press twice. To clear all characters, press three times. To accept an entry, press down on the scroll control or press E. 12 How the Scanner's Controls Are Represented in This Manual To help navigate the scanner's menus, the steps shown in this manual show the displays you see and the keys you press or control you operate to get a desired result. This example shows you how to use the scanner's menu to edit an existing system name. It shows you the key to press ( Menu ) to select a menu option and the option you see (Program System) when you press Menu . It also instructs you to turn the scroll control (shown as ) to view a series of choices then press the scroll control (shown as (Edit Name). Menu ) to select a choice Program System Select the system Edit Name Follow these steps to enter/edit the system name. 1. The first character of the system name is covered by a cursor. Rotate the scroll control to select the character you want. 2. Press 6/ on the keypad to select the next character. The cursor moves to the next character. To move the cursor to a previous character, press /4. 3. Repeat Steps 1 and 2 until you have entered the system name. Then press down on the scroll control or press E to accept the setting. Hints: · Each system name can be up to 16 characters. Abbreviate as necessary to fit. · Press · Press twice to delete the current character. three times to clear the entire alpha tag. Feature Highlights 13 To get the most from this manual, review the contents to become familiar with the basic functions available. If you are new to scanning, be sure to read "Understanding Scanning" on Page 15 for a quick background on the technology. The first thing you'll need to do is install batteries in the scanner. Then you need to connect the included antenna to the scanner. See "Setting Up Your Scanner" on Page 20 if you need any help doing this. 14 Understanding Scanning This section provides Scanning Understandingyou with background on how scanning works. You don't really need to know all of this to use your scanner, but some background knowledge will help you get the most from your UBC3500XLT. Understanding the Scanner's Memory Your scanner's memory is organized in an architecture called Dynamic Allocated Channel memory. This type of memory is organized differently and more efficiently than the bank/channel architecture used by traditional scanners. Dynamic Allocated design matches how radio systems actually work much more closely, making it easier to program and use your scanner and determine how much memory you have used and how much you have left. Instead of being organized into separate banks and channels, your scanner's memory is contained in a pool. You simply use as much memory as you need in the pool to store as many frequencies and alpha tags as you need. No memory space is wasted, and you can tell at a glance how much memory you have used and how much remains. What is Scanning? Unlike standard AM or FM radio stations, most twoway communications do not transmit continuously. Your UBC3500XLT scans programmed channels until it finds an active frequency, then stops on that frequency and remains on that channel as long as the transmission continues. When the transmission ends, the scanning cycle resumes until the scanner receives another transmission. What is Searching? The UBC3500XLT can search each of its bands and up to 10 bands together to find active frequencies. Understanding Scanning 15 This is different from scanning because you are searching for frequencies that have not been programmed into the scanner. When you select frequency bands to search, the scanner searches for any active frequency within the lower and upper limits you specify. When the scanner finds an active frequency, it stops on that frequency as long as the transmission lasts. If you think the frequency is interesting, you can program it into the scanner's memory. If not, you can continue to search. What is CTCSS/DCS? Your scanner can monitor systems using a Continuous Tone Coded Squelch System (CTCSS) and Digital Coded Squelch (DCS) system, which allow squelch to open only when the tone you have programmed with a specific frequency is received along with a transmission. CTCSS and DCS are subaudible tone signaling systems sometimes referred to as PL or DPL (Motorola's trademarked terms for Private Line and Digital Private Line respectively). CTCSS and DCS are used only for FM signals and are usually associated with both amateur and commercial twoway frequencies. These systems make use of a special subaudible tone that accompanies a transmitted signal. CTCSS and DCS are used for many purposes. In many cases, CTCSS and DCS are used to restrict access to a commercial repeater, so that only those units which transmit the correct tone along with their signal can "talk" to the repeater. CTCSS and DCS are also used in areas that receive interference where there are several stations with output frequencies close to each other. When this occurs, you might hear multiple communications on the same frequency. The stations might even interfere 16 with each other to the point where it is impossible to clearly receive any of the stations. A scanner equipped with CTCSS and DCS (like your scanner) can code each received frequency with a specific CTCSS or DCS frequency. Then, when you receive multiple signals, you only hear the transmission with the CTCSS or DCS tone you programmed. If you do not receive the correct tone with a signal, the scanner's squelch remains closed and you hear nothing. You can search for the following CTCSS frequencies and DCS codes. CTCSS Frequencies (Hz) 67.0 82.5 100.0 123.0 151.4 171.3 189.9 210.7 69.3 85.4 103.5 127.3 156.7 173.8 192.8 218.1 71.9 88.5 107.2 131.8 159.8 177.3 196.6 225.7 250.3 74.4 91.5 110.9 136.5 162.2 179.9 199.5 229.1 254.1 77.0 94.8 114.8 141.3 165.5 183.5 203.5 233.6 79.7 97.4 118.8 146.2 167.9 186.2 206.5 241.8 DCS Codes (Octal) 023 051 114 143 174 245 266 332 411 025 053 115 145 205 246 271 343 412 026 054 116 152 212 251 274 346 413 031 065 122 155 223 252 306 351 423 032 071 125 156 225 255 311 356 431 036 072 131 162 226 261 315 364 432 043 073 132 165 243 263 325 365 445 047 074 134 172 244 265 331 371 446 Understanding Scanning 17 452 506 612 703 454 516 624 712 455 523 627 723 462 526 631 731 464 532 632 732 465 546 654 734 466 565 662 743 503 606 664 754 Conventional Scanning Conventional scanning is a relatively simple concept. Each group of users in a conventional system is assigned a single frequency (for simplex systems) or two frequencies (for repeater systems). Any time one of them transmits, their transmission always goes out on the same frequency. Today there are still many 2-way radio users who operate using a conventional system: · · · · · Aircraft Amateur radio LPD/PMR users Broadcast AM/FM/TV stations Many business radio users When you want to store a conventional system, all you need to know is the frequencies they operate on. When you are scanning a conventional system, the scanner stops very briefly on each channel to see if there is activity. If there isn't, the scanner quickly moves to the next channel. If there is, then the scanner pauses on the transmission until it is over. Simplex Operation Simplex systems use a single frequency for both transmit and receive. Most radios using this type of operation are limited to line-of-sight operation. This type of radio is frequently used at construction job sites, and with inexpensive consumer radios such as LPD/PMR radios. The range is typically 1-5 km, depending upon the terrain and many other factors. 18 Repeater Operation Repeater systems use two frequencies: one transmits from the radio to a central repeater; the other transmits from the repeater to other radios in the system. With a repeater-based system, the repeater is located on top of a tall building or on a radio tower that provides great visibility to the area of operation. When a user transmits (on an input frequency), the signal is picked up by the repeater and retransmitted (on an output frequency). The user's radios always listen for activity on the output frequency and transmit on the input frequency. Since the repeater is located very high, there is a very large line of sight. Where To Get More Information By itself, this manual really only provides part of what you need to know to have fun scanning ­ how to program and use the scanner. Information On The Internet The Internet is a great source for current frequencies and information about scanning. Many web sites have lists of frequencies for your area. You can use a search engine to find and use them. Make a list of the agencies you want to listen to, then look up the frequencies and systems used by those agencies. · www.racescanner.eu - Race frequency information, programming software and accessories. Understanding Scanning 19 Included With Your Scanner Included With Your Scanner Wrist Strap AC Adapter Batteries Scanner (with antenna attached) Belt Clip BNC/SMA Adapter Owners Manual and other printed material Setting Up Your Scanner 20 Setting Up Your Scanner These guidelines will help you install and set up your new scanner: · If your scanner receives interference or electrical noise, move the scanner or its antenna away from the source. · To improve the scanner's reception, use an optional external antenna designed for multi-band coverage. (You can purchase this type of antenna at a local electronics store). If the optional antenna has no cable, use 50-75 coaxial cable for leadin. A mating plug might be necessary for the optional antennas. · Use an optional mono earphone or mono headset with proper impedance (32 ) for private listening. Read the precautions on the inside front cover of this Owners Manual. · Do not use the scanner in high-moisture environments such as the kitchen or bathroom. · Avoid placing the scanner in direct sunlight or near heating elements or vents. Using Internal Batteries You can power your scanner using three alkaline or rechargeable AA batteries. Before installing batteries, set the switch in the battery compartment to match the type of batteries you will use. Select ALKALINE for non-rechargeable battery types and Ni-MH for rechargeable battery types. See also "Using Rechargeable Batteries" on Page 22 when you use rechargeable batteries. 1. Remove the battery cover and set the battery switch. Setting Up Your Scanner 21 2. Install 3 AA batteries, matching the polarity symbols (+ -). WARNING! Set ALKALINE/Ni-MH to Ni-MH for use only with rechargeable batteries. Never attempt to recharge non-rechargeable batteries. Non-rechargeable batteries can get hot and can even burst if you try to recharge them. 3. Replace the cover. When flashes and the scanner beeps every 15 seconds, replace the batteries. Using Rechargeable Batteries You can also use three rechargeable batteries to power your scanner. Before you use rechargeable batteries, you must charge them. The scanner has a built-in circuit that lets you recharge batteries while they are in the scanner. To charge the batteries, set ALKALINE/ Ni-MH inside the battery compartment to NI-MH, install the batteries in the scanner, and connect the supplied AC adapter to the scanner's DC 6V jack (see "Using AC Power" on Page 23). WARNING! Do not connect the AC adapter to the scanner if non-rechargeable batteries (such as alkaline batteries) are installed in the scanner and ALKALINE/Ni-MH is set to NI-MH, or if you are unsure of the switch's position. Non-rechargeable batteries can get hot and can even burst if you try to recharge them. Before you use rechargeable batteries for the first time, charge them for 14 hours to bring them to a full charge. Discharged batteries take about 14 hours to fully recharge. 22 If an AC adapter is connected to the scanner, the scanner checks the condition of the installed batteries. If the scanner is turned off and the batteries require a full charge, Normal Charging appears as the batteries are recharged. When the batteries are fully charged, Charge Complete appears. If no batteries are installed in the scanner, No Battery appears. If there is a problem with the installed batteries, Battery Error appears. If the installed batteries are Ni-MH batteries but ALKALINE/Ni-MH is set to ALKALINE, Charge Off appears and the scanner does not charge the batteries. Removing the Display Sticker Before you use the scanner, remove the protective plastic sticker over the display. Using AC Power You can power the scanner using the supplied 6V, 800 mA AC adapter. To use the scanner on AC power, plug the adapter into 6V 800 mA on the right side of the scanner, then plug the AC adapter into a standard AC outlet. If rechargeable batteries are installed and ALKALINE/ Ni-MH is set to NI-MH, the adapter powers the scanner and recharges the installed batteries at the same time. WARNING! To prevent damage to Ni-MH batteries, never charge them in an area where the temperature is above 45°C (113°F) or below 4°C (40°F). Setting Up Your Scanner 23 Connecting the Antenna To attach the supplied flexible antenna to the connector on the top of your scanner, simply screw it onto the scanner's SMA connector. Connecting an Optional Antenna The scanner's SMA connector makes it easy to connect a variety of optional antennas, including an external mobile antenna or outdoor base station antenna. Note: Always use 50- or 75-ohm, RG-58, or RG-8, coaxial cable and the supplied BNC/SMA adapter to connect an outdoor antenna. If the antenna is over 50 feet from the scanner, use RG-8 low-loss dielectric coaxial cable. Cable loss increases with higher frequency. Connecting an Earphone/Headphone For private listening, you can plug a 1/8-inch (3.5 mm) mini-plug earphone or headphones (not supplied) into the headphone jack on top of your scanner. This automatically disconnects the internal speaker. See "Earphone Warning" at the front of the manual for important information about using an earphone/ headphone. Connecting an Extension Speaker In a noisy area, an optional amplified extension speaker, positioned in the right place, might provide more comfortable listening. Plug the speaker cable's 1 /8-inch (3.5-mm) mini-plug into your scanner's jack. WARNING! Never connect anything other than an earphone or the recommended amplified extension speaker to the scanner's headphone jack. This might damage the scanner. 24 WARNING! Never connect any part of the headphone jack to the antenna jack or connect the radio to an installation where the antenna and audio connection are grounded. This might damage the scanner. Attaching the Belt Clip To make your scanner easier to carry when you are on the go, use the supplied belt clip. Rotate the scanner upside down to remove it from the clip. Attaching the Wrist Strap To keep your scanner safely close at hand, use the supplied wrist strap. Push the small loop on one end of the wrist strap through the lug on the right side of the scanner, then thread the other end of the wrist strap back through the small loop to secure it. A Look At The Keypad car Your scanner's keys have various functions labeled on the key tops and below the keys. To select the function labeled on a key, simply press the key. To select the function labeled below a key, hold down Func on the left side of the scanner then press the key. F appears on the display. Setting Up Your Scanner 25 If your scanner's keys seem confusing at first, the following information should help you understand each key's function. Key Name Hold/ Description Hold ­ Holds the scan or the frequency search when pressed. Resumes the scan or the frequency search when pressed again. Release the mute when pressed in Tone-Out Standby mode. Func + ­ Quickly turns the Close Call feature on or off (see "Setting Close Call Options" on Page 66). Scan/srch Scan ­ Scans the stored channels. + srch ­ Starts quick search or quickly accesses the search menu. Func L/O L/O ­ Lets you lock out a selected channel or skip a specified frequency. Press and hold for more than 2 seconds to unlock all channels in a system or all frequencies in a Search mode and Close Call mode. Also use to exit a menu. Func + L/O ­ Press quickly to lock and unlock a selected system in Scan or Scan Hold mode and review search lockout frequencies in Search or Search Hold mode. 26 Key Name / / Description ­ Turns the display backlight on or off. Press and hold for more than 2 seconds to turn the scanner on or off. Func + ­ Locks and unlocks the keypad. 0-9 0-9 ­ Enters a frequency, enters quick key numbers, and selects a custom search range in Custom Search mode. Selects systems by quick key in scan mode. Func + 0-9 ­ Selects groups by quick key in scan mode. 1/pri 1 ­ Enters a 1. Func + pri ­ Selects the priority mode in scan hold mode. /4 4 ­ Enters a 4. Func + ­ Moves the active character to the left while editing data. 6/ 6 ­ Enters a 6. Func + ­ Moves the active character to the right while editing data. 7/rcl 7 ­ Enters a 7. Func + rcl ­ Displays a series of prompts to quickly select a specific channel in the scan hold mode. Setting Up Your Scanner 27 Key Name /no/rev Description ­ Enters a decimal point or dash in a frequency, enters or selects an extended 2-digit Quick Key. At a prompt, answers "No." + rev ­ Monitors the currently-tuned frequency's reverse frequency. Func E/yes/att E ­ Press to select input and menu items, to quickly edit a channel in Scan Hold Mode, and store a frequency into memory in Search Hold mode. At a prompt, answers "Yes." Func + att ­ Turns the scanner's attenuator on or off for the current channel or frequency. A Look At The Display The display has indicators that show the scanner's current operating status. The display information helps you understand how your scanner operates. Sn: - appears with a number to show the currentlyselected System Quick Key number. n appears to show the first digit of the Quick Key number. For example, if System Quick Key 75 is selected, S7: appears. The currently active system indicator flashes. ATT - appears when the attenuation feature is turned on. See "Setting Attenuation" on Page 73, and "Setting Channel Attenuation" on Page 56. PRI - appears when the priority feature is turned on (see "Priority Scan" on Page 39). 28 - appears when you lock the keypad (see "Locking/Unlocking the Keypad and Scroll" on Page 38). - alerts you when the battery power gets low. GRP - shows the currently activated group or selected group Quick Key number, appears with numbers (0-9). The currently active group indicator flashes. AM/FM/NFM/WFM/FMB - appears to show the type of reception mode. L/O - appears when you manually select a channel you locked out or a skip frequency. F - appears when you hold down function. Func to select a - appears when the scanner is set to CC Pri Mode (see "Using the Close Call Feature" on Page 65). - appears when the scanner is set to Close Call DND Mode. (see "Using the Close Call Feature" on Page 65). SCAN - scrolls while the scanner is scanning. DSKP - appears when data skip is turned on. HOLD - appears while the scanner is set to scan or search hold mode. P - appears if priority is turned on SCR - appears when one or more broadcast screen bands are turned on. - appears to show signal strength (0 to 5). Setting Up Your Scanner 29 Using Menu Func Menu Press Menu on the left side of the scanner to enter the menu. See "Using the Menu" on Page 36 for more information about the scanner's menu options. Using Func To select the function labeled below a key on the front of the scanner, hold down Func on the left side of the scanner, then press that key. To hold on a system while scanning or temporarily stop on a channel while searching, press Func . To select a system in Scan or Scan Hold mode, hold down Func and rotate the scroll control. 30 Basic Operation Basic Operation Scanner and Turning On the Setting the Squelch Scroll Control Note: Make sure the scanner's antenna is connected before you turn it on. 1. Press and hold the scanner. for about 2 seconds to turn on 2. Briefly press the scroll control once. VOLUME LEVEL and a number appear on the display. Amateur Radio 145.2000MHz 3. While VOLUME LEVEL appears, rotate the scroll control to set the volume to a comfortable listening level. Note: If you do not press any key or turn the scroll control within about 10 seconds, VOLUME LEVEL disappears. If this happens, simply press the scroll control again. 4. While holding down Func on the left side of the scanner, briefly press the scroll control once. SQUELCH LEVEL and a number appear on the display. 5. While SQUELCH LEVEL appears, rotate the scroll control to set the squelch to the level you want. Note: If you do not press any key or turn the scroll control within about 10 seconds, SQUELCH LEVEL disappears. If this happens, hold down Func and the scroll control again. Basic Operation 31 Scanning Systems To begin scanning programmed systems, press Scan. The UBC3500XLT scans all unlocked systems in all activated quick-key groups and any searches unlocked for search and scan. Notes: · If no systems are programmed, or all systems are locked out, an error message appears. Program a system or select a system to scan. · When scanning multiple systems, the UBC3500XLT scans systems according to the assigned quick key. Systems assigned to quick key 1 are scanned first, then 2, 3, 4, etc. Systems not assigned to a quick key are scanned last, then unlocked searches. Within a quick key, systems are scanned in the order they were assigned. · Within a system, channels are scanned according to the assigned channel group, with the same priority as described above for systems. · The UBC3500XLT scans a system for the duration you set using the System Hold Time option (see "Setting the System Hold Time" on Page 47). Conventional systems operate similarly, but all unlocked channels are scanned at least one time regardless of the hold time setting. · Each search range is searched for the amount of time you set using the "Set Hold Time" option. See "Setting the System Hold Time" on Page 47 for more information. Selecting Systems to Scan To select systems to scan, press Scan then press the quick key assigned to the system or systems you want to scan. For quick keys 0-9, press the quick key's number. For quick keys 10-99, press then press the 32 quick key's 2-digit number. To stop scanning the system(s), press (if the quick key is a 2-digit quick key) then the number button or buttons again. The Sx: (system) indicators on the display show the systems that are currently selected. To select or lock out a system that is not assigned to a key, press and hold Func while you rotate the scroll control until the desired system is selected. Then, continue to hold Func and press L/O to either lock out or unlock the system. Selecting System Channel Groups Within a system, you can assign groups of channels to a group quick key (see "Setting the Group Quick Key" on Page 50). Follow these steps to activate or deactivate a channel group within a system while scanning. 1. Press Func to hold on the system (or hold down Func then rotate the scroll control to select the system). 2. Continue to hold Func and press the number key corresponding to the channel group you want to activate or deactivate. Locking/Unlocking Systems Follow these steps to lock out a system so that it does not scan even if its quick key is selected. 1. While holding down Func , rotate the scroll control to select the system. 2. Continue to hold down Func and press L/O to lock out the system. System Locked appears. 3. Repeat Steps 1 and 2 to unlock a system you have previously locked. System Unlocked appears. Basic Operation 33 Locking/Unlocking Channels Follow these steps to lock out a channel so that it does not scan even if its system and channel group are selected. 1. While holding down Func , rotate the scroll control to select the system where the channel is stored. 2. Release Func then press Hold within 2 seconds to hold on the system. 3. Rotate the scroll control to select the channel you want to lock or unlock. 4. Press L/O to lock or unlock the channel. You can also lock out an active channel by pressing L/O while the scanner is stopped on the channel. Temporarily Holding On a System To temporarily hold on a system, press and hold Func . To hold on a different system, continue to hold Func and rotate the scroll control to select the system. Normal scanning resumes 2 seconds after you release Func . Holding On a Channel To hold on a channel, press Hold while the channel is active. To select a different channel, rotate the scroll control. If you scroll past the beginning or end of the current system, the scanner selects channels in the previous or next system. To resume scanning, press Scan. Quick-Storing Channels 1. Hold on an existing channel in any system. 2. Enter the frequency you want to store. 3. To quick-store the channel, press E. Otherwise, press . If you enter a frequency then press E, the scanner stores it in the Qck Save Grp group in a system 34 called Qck Save Cnv Sys. These are created if they do not exist. Then, the scanner prompts you to save other channel settings. If you pressed No in Step 3, the scanner prompts you to select the system where you want to store the frequency. Quickly Recalling Channels 1. Press Hold to hold on any channel. 2. Press Func + rcl. The scanner prompts you to select the system where the channel is stored. 3. Rotate the scroll control to select the system, then press E. The scanner prompts you to select the channel group where the channel is stored. 4. Rotate the scroll control to select the group, then press E. The scanner prompts you to select a channel. 5. Rotate the scroll control to select the channel, then press E to hold on that channel. Toggling Channel Alpha Tags To change the display so the frequency appear instead of the alpha tag, press Func + 5. Basic Operation 35 Using the Menu The scanner's menu Using the Menulets you select options that let you set up and use the scanner. To use the menu, press Menu on the left side of the scanner. To select a menu item, rotate the scroll control clockwise or counterclockwise. The currentlyselected menu item is highlighted with a bar on the display. When the menu item you want to select is highlighted, briefly press the scroll control to select it. To back up a level, press Menu . To exit the menu mode, press Menu again or the L/O key. This table shows the scanner's menu structure. To find information about a particular menu setting in this manual, go to the page number shown in parentheses next to the setting. Note: Not all of the options shown in this table may appear at the same time. To view all available options on any screen, rotate the scroll control. Menu Item -- M E N U -Program System Srch/CloCall Opt Search for ... Submenu Select System New System (32) -- M E N U -Program System Srch/CloCall Opt Search for ... Srch/CloCall Opt Freq Lockouts Broadcast Screen CTCSS/DCS Search Srch/CloCall Opt Max Auto Store Set Delay Time Set Modulation Set Attenuator Set Data Skip Set Step Air Band Step Search for ... Service Search Edit Service Custom SearchOpt Srch/CloCall Edit Custom Search and Store (70) (71) (16) (72) (74) (55) (72) (73) (73) (74) (75) -- M E N U -Program System Srch/CloCall Opt Search for ... (59) (62) (60) (61) (63) 36 Menu Item -- M E N U -Srch/CloCall Opt Search for ... Close Call Submenu Close Call Close Call Only CC Auto Store Set CC Mode Set CC Override Set CC Alert Set CC Bands Set Priority Off On Plus On Srch/CloCall Opt (66) (66) (66) (67) (67) (68) (39) (39) (39) (39) -- M E N U -Search for ... Close Call Set Priority -- M E N U -Set Priority Tone-Out for ... Wired Clone Tone-Out for ... Tone-Out Standby Tone-Out Setup h/ l ll (76) (76) -- M E N U -Set Priority Tone-Out for ... Wired Clone Wired Clone Master Slave Srch/CloCall Opt (42) (42) -- M E N U -Tone-Out for ... Wired Clone Settings Settings Set Backlight Adjust Key Beep Set Battery Save Srch/CloCall Opt Set Audio AGC Adjust Contrast PC Control See Scanner Info (39) (38) (39) (40) (40) (40) (38) Using the Menu 37 Settings Settings System Information Displaying Viewing Memory Used Menu Settings See Scanner Info % Memory Used A bar showing the percent of memory used appears. Press any key to return to the previous menu. Viewing the Firmware Version Menu Settings See Scanner Info Firmware Version Press any key to return to the previous menu. Adjusting the Key Beep Menu Settings Adjust Key Beep Auto - the scanner automatically sets the key beep to match the master volume setting level you select. Level 1 - 15 the scanner lets you select a key beep level. You can choose any of 15 different key beep levels. Off - the scanner turns the key beep off. Locking/Unlocking the Keypad and Scroll Press and hold down Func then press / / to lock or unlock the keypad. Keypad Lock and On (if the keypad is locked) or Off (if the keypad is unlocked) appears. This does not affect the volume setting. The scroll control still controls the volume when you lock the controls. 38 Turning Power Save On or Off Menu Settings Set Battery Save · On The scanner goes into low-power mode when you monitor a conventional channel that has no activity. · Off Power save is off. Priority Scan Menu Set Priority Or, while holding on any channel in Scan Mode, press Func + 1/pri to select one of these priority modes: · Off Normal scanning · On While scanning a conventional system, the scanner interrupts every 2 seconds and checks the priority channels in each unlocked conventional system. Priority channels in lower quick key numbered systems (starting from 1) have highest priority. PRI appears when you select this mode. · Plus On The scanner only scans priority channels in unlocked conventional systems. PRI flashes when you select this mode. Using the Backlight Menu Settings Set Backlight · 10 sec The backlight stays on for 10 seconds after you press . · 30 sec The backlight stays on for 30 seconds after you press . · Squelch The backlight turns on when the squelch opens then stays on for 5 seconds. · Keypress The backlight turns on when any key is pressed then stays on for 10 seconds. · Infinite The backlight turns on when you press then stays on until you press again. Settings 39 Pressing any key while the backlight is on extends the backlight period. Pressing while the backlight is on turns off the backlight. Setting the Audio AGC Menu Settings Set Audio AGC This setting helps balance the audio level you hear as you listen to different radio sources so you can hear them at a similar volume. Use this setting if you listen to an audio source that has natural changes in audio level for which you want to compensate. · On Press the scroll control to select. Audio AGC is turned on. · Off Press the scroll control to select. Audio AGC is turned off. Adjusting the Display Contrast Menu Settings Adjust Contrast Contrast 1 - 15 the scanner adjusts the display to the contrast level you select. This setting controls the display's contrast (how light or dark it appears). Use this setting to change the contrast for different viewing conditions. There are 15 contrast settings. You see the change in contrast as you scroll through the settings. Initializing the Scanner's Memory 1. Turn off the scanner. 2. Press 2, 9, and Hold while turning on the scanner. All Memory Clear Please Wait appears. Connecting Your Scanner to a Personal Computer To connect your scanner to a personal computer, you must first set the scanner's baud rate (the rate at 40 which data is transferred between the scanner and the computer, in bits per second (bps). Important! Before you start transferring data between your scanner and your computer, make sure the batteries are fresh or fully charged. If the scanner loses power while you are transferring data, its memory might be corrupted and all information programmed in the scanner might be erased. Hint: If you have trouble transferring data between your scanner and your computer, try setting the baud rate to a slower setting. Use the optional connection cable to connect your scanner to another UBC3500XLT scanner or your personal computer. Optional software is available at http://www.racescanner.eu. Menu Settings PC Control PC Control Lets you set the baud rate your scanner uses to communicate with a personal computer. · · · · · · Off The baud rate is not set. 9600 bps The baud rate is set to 9600 bps. 19200 bps The baud rate is set to 19,200 bps. 38400 bps The baud rate is set to 38,400 bps. 57600 bps The baud rate is set to 57,600 bps. 115200 bps The baud rate is set to 115,200 bps. Using the Cloning Options Lets you set your scanner as a master (source) or slave (recipient), letting you transfer programming to or from another UBC3500XLT scanner. See "Wired Cloning" on Page 42. Settings 41 Wired Cloning Menu Wired Clone · Master Sets the scanner to be the source scanner. · Slave Sets the scanner to be the recipient scanner. To clone (copy) data directly from one UBC3500XLT scanner to another UBC3500XLT scanner, you must first connect the scanners to each other using the included connection cables and a DB9 null modem adapter and DB9 gender changer (neither included), available at most computer stores. Then you must set one scanner as the source and the other as the destination. Plug the smaller end of each of the included connection cables into Remote on the right side of each scanner. Then connect the other end of the cables together using the null modem connector and gender changer. Then set the scanner containing the programming you want to transfer as the master scanner, then set the other scanner as the slave scanner. (Master scanner) Clone Master Press SCAN Key Scan (Slave scanner) Clone Slave Press SCAN Key Scan When you are ready to clone the scanner, press Scan on the slave scanner first, then on the master scanner. The master scanner checks the connection between the two scanners, then transfers its data to the slave scanner. When the transfer is complete, Complete appears on both scanners. If the transfer did not work, Error appears on the master scanner. 42 Programming Radio Systems To get the most enjoyment from your scanner, you Programming Radio Systems must customize the programming for your area. Use the menu to navigate to the system setting you want to customize. Programming radio systems is completed in two major steps. Don't skip either step! 1. Plan the system. 2. Program the system into your scanner according to the plan you prepared in Step 1. To make planning easier, planning worksheet is included in the back of this manual for each system type. Copy the worksheet or download the worksheet from http://www.racescanner.eu and print extra sheets), then use them to plan out how you will program the scanner. Important! Before you start programming your scanner, make sure the batteries are fresh or fully charged. If the scanner loses power while you program it, its memory might be corrupted which will require you to reinitialize it (see "Initializing the Scanner's Memory" on Page 40). All information programmed in the scanner, including preprogrammed systems, might be lost. General Notes · You can store up to 200 systems. · You can store up to 20 channel groups per system. · Total channels are limited to 2,500 Programming Conventional Systems Menu Program System New System The scanner creates an empty conventional system, with a default name of System n. n is a number that increments as you add new systems. Programming Radio Systems 43 Refer to the appropriate section to set system-wide options: · · · · · · · · · See "Editing the System Name" on Page 46 See "Editing the System Quick Key" on Page 46 See "Setting System Lockout" on Page 47 See "Setting the System Hold Time" on Page 47 See "Setting the Channel Delay Time" on Page 48 See "Setting the Data Skip" on Page 48 See "Deleting Systems" on Page 49 See "Copying Systems" on Page 49 See "Entering/Editing Conventional Channel Groups" on Page 44 Entering/Editing Conventional Channel Groups To enter channels in a conventional system, first set up a channel group (or groups) to hold the channels. Then, enter the channel and channel parameters in the group(s). Setting Up a Channel Group Menu Program System Select the system Edit Group New Group The scanner creates a group with a default name of Group n. n increments by one for each new group you create within a system. Refer to the appropriate section to set group-wide options: · See "Entering/Editing the Group Name" on Page 49 · See "Setting the Group Quick Key" on Page 50 · See "Deleting Groups" on Page 51 · See "Setting Group Lockout" on Page 51 · See "Entering/Editing Conventional Channels" on Page 45 44 Entering/Editing Conventional Channels Menu Program System Edit Group Select the system Select the group Edit Channel New Channel Refer to the appropriate section to change a channel setting: · · · · · See "Editing the Channel Name" on Page 51 See "Editing Frequencies" on Page 52 See "Setting Channel Priority" on Page 53 See "Deleting Channels" on Page 57 See "Copying/Pasting Channels" on Page 57 Note: The scanner automatically sets the step to match the input frequency. Programming Radio Systems 45 Programming/Editing Optional Settings This section details the instructions for each of the tings Programming/Editing Optional Setoptional programming steps referred to in "Programming Radio Systems" on Page 43. Use the instructions in the appropriate section to enter or edit a setting. System-Level Settings Editing the System Name Menu Program System Select the system Edit Name To enter a letter, turn the scroll control until the character you want appears. To enter a decimal point, press . To move the cursor to the left, press /4 or hold Func and rotate the scroll control to the left. To move the cursor to the right, press 6/ or hold Func and rotate the scroll control to the right. To clear a character, press twice. To clear all characters, press 3 times. To accept an entry, press E or press down on the scroll control. Hints: · Each system name can be up to 16 characters. Abbreviate as necessary to fit. Editing the System Quick Key Menu Program System Select the system Edit Sys Option Set Quick Key After selecting this option, select any number from 1-99 to assign the system to a quick key or press to assign the system to no quick key, then press E. 46 Hints: · Access single-digit system Quick Keys by pressing the single digit on the keypad during scanning. Access two-digit system Quick Keys by pressing then both digits. · You can assign as many systems to the same quick key as you want. · To be scanned, a system's quick key must be activated and the system must be unlocked. Setting System Lockout Menu Program System Select the system Edit Sys Option Set Lockout This setting controls whether the system is scanned when its quick key is enabled. Rotate the scroll control to select your setting, then press E. Lockout - the system is not scanned Unlocked - the system is scanned Note: You can also lock or unlock a system by holding Func and rotating the scroll control to select the system, then pressing Func + L/O. Setting the System Hold Time Menu Program System Select the system Edit Sys Option Set Hold Time This setting controls how many seconds the scanner scans a system before moving to the next unlocked system. Enter a value from 0-255, then press E to save the setting. Programming/Editing Optional Settings 47 Notes: · If you select 0, the scanner stays on the system for a minimal time (only long enough to check current system activity). · The default setting is 2 seconds for each system. · For conventional systems, all unlocked channels will be scanned at least once regardless of this setting. · The scanner moves to the next system after the hold time expires, any current transmission ends, and the channel delay time expires. Setting the Channel Delay Time Menu Program System Select the system Edit Sys Option Set Delay Time This setting controls how many seconds the scanner waits after a transmission ends before resuming scanning. Enter a value from 1-5 or Off, then press E or the scroll control. Notes: · The default setting is 2 seconds for each system. · This setting applies to all channels within the system. Setting the Data Skip Menu Program System Select the system Edit Sys Option Set Data Skip This setting controls how the scanner behaves when it stops on a channel that has a data signal. 48 On - The scanner ignores the Data Signal and resumes searching in a few seconds. Off - The scanner treats all signals as normal transmission. Deleting Systems Menu Program System Select the system Delete System The scanner prompts you to confirm deletion. To confirm, press E. To cancel, press . Notes: · Deleted systems cannot be restored. You must re-enter them. · You cannot restore preloaded systems. Copying Systems To copy a system including all settings, groups, and channels: Menu Program System Select the system Copy System New Sys Name? Enter a name for the copied system, then press E. Group-Level Settings The settings in this section apply to all of the channels stored in the current group. Entering/Editing the Group Name Menu Program System Select the system Edit Group Programming/Editing Optional Settings 49 Select the group Edit Name Follow these steps to enter/edit the group name. 1. Rotate the scroll control to select the first letter. 2. Press /4, or hold Func then rotate the scroll control to the left. To move the cursor to the right, press 6/ or hold Func and rotate the scroll control to the right. 3. Repeat Steps 1 and 2 until you have entered the system name. Then press E or press down on the scroll control to accept the setting. Hints: · Each group name can be up to 16 characters. Abbreviate as necessary to fit. · The group and system name alternate in the top line of the display when the scanner stops on a channel. · Press · Press twice to delete the current character. three times to clear the entire alpha tag. Setting the Group Quick Key Menu Program System Select the system Edit Group Select the group Set Quick Key After selecting this option, press 0-9 to assign the group to a quick key or press to assign the group to no quick key, then press E. Hints: · You can assign as many groups to the same quick key as you want. · A group's quick key must be activated to be scanned. 50

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual UNIDEN UBC3500XLT.

UNIDEN offer a product for which we do not have the user manual? Let us know what you are looking for: user guide, owner's manual, online manual, operating instructions, quick start guide, mounting instructions, schematics, service manual, installation instructions, RTFM.

Diplodocs allows you to download user manual UNIDEN UBC3500XLT, user guide UNIDEN UBC3500XLT, instructions UNIDEN UBC3500XLT, owner's manual UNIDEN UBC3500XLT, online manual UNIDEN UBC3500XLT.


UNIDEN UBC3500XLT, , GPS & Navigation Kit.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.