Detailed instructions for use are in the User's Guide.
USP Anchor to Connector Guide
2005
Cross Reference Guide for use with the USP Structural Connectors Full Line Catalog and the USP Anchoring Systems Technical Guide
USP supplies quality products to build Stronger Safer Structures
Rancho Cucamonga · Livermore · Montgomery · Houston · Largo · North Wilkesboro · Lumberton · Long Beach · Thornhill, Ontario
2
Index
BP12/HBPS12/LBP12 . . . . . . . . . .6 BP58/LBP58 . . . . . . . . . . . . . . . . .7 HTT16 . . . . . . . . . . . . . . . . . . . . . .8 HTT22 . . . . . . . . . . . . . . . . . . . . . .9 HTT30 . . . . . . . . . . . . . . . . . . . . .10 HTT50 . . . . . . . . . . . . . . . . . . . . .11 LTS19 . . . . . . . . . . . . . . . . . . . . .12 LTS20 . . . . . . . . . . . . . . . . . . . . .13 LTS20B . . . . . . . . . . . . . . . . . . . .14 MTS 27B . . . . . . . . . . . . . . . . . . .15 PA44 /PA44R . . . . . . . . . . . . . . . .16 PA46/PA46R . . . . . . . . . . . . . . . .16 PA66/PA66R . . . . . . . . . . . . . . . .16 PA88/PA88R . . . . . . . . . . . . . . . .16 PA44E . . . . . . . . . . . . . . . . . . . . .17 PA46E . . . . . . . . . . . . . . . . . . . . .18 PA66E . . . . . . . . . . . . . . . . . . . . .18 PAU44 . . . . . . . . . . . . . . . . . . . . .19 PAU46 . . . . . . . . . . . . . . . . . . . . .19 PAU66 . . . . . . . . . . . . . . . . . . . . .19 PAU88 (/R) . . . . . . . . . . . . . . . . .20 PHD2 . . . . . . . . . . . . . . . . . . . . . .21 PHD5 . . . . . . . . . . . . . . . . . . . . . .22 PHD6 . . . . . . . . . . . . . . . . . . . . . .23 PHD8 . . . . . . . . . . . . . . . . . . . . . .24 PHDN16 . . . . . . . . . . . . . . . . . . .25 SFA6 . . . . . . . . . . . . . . . . . . . . . .26 SFA8 . . . . . . . . . . . . . . . . . . . . . .26 SFJA . . . . . . . . . . . . . . . . . . . . . .27 TD2 . . . . . . . . . . . . . . . . . . . . . . .28 TD5 . . . . . . . . . . . . . . . . . . . . . . .29 TD6 . . . . . . . . . . . . . . . . . . . . . . .30 TD7 . . . . . . . . . . . . . . . . . . . . . . .31 TD9 . . . . . . . . . . . . . . . . . . . . . . .32 TD12 . . . . . . . . . . . . . . . . . . . . . .33 TD15 . . . . . . . . . . . . . . . . . . . . . .34 TD8S . . . . . . . . . . . . . . . . . . . . . .35 TD10S . . . . . . . . . . . . . . . . . . . . .36 TDL5 . . . . . . . . . . . . . . . . . . . . . .37 TDL10 . . . . . . . . . . . . . . . . . . . . .37 TDX2 . . . . . . . . . . . . . . . . . . . . . .38 TDX5 . . . . . . . . . . . . . . . . . . . . . .39 TDX6 . . . . . . . . . . . . . . . . . . . . . .40 TDX8 . . . . . . . . . . . . . . . . . . . . . .41 TDX10 . . . . . . . . . . . . . . . . . . . . .42 TDX14 . . . . . . . . . . . . . . . . . . . . .43 TDX20 . . . . . . . . . . . . . . . . . . . . .44 UPHD8 . . . . . . . . . . . . . . . . . . . .45
Listings/Approvals:
ICC (ICBO)-ES ESR-1702, LA City RR 25113 & RR 25029, Caltrans + most other state DOT's Meets ASTM C-881 & AASHTO M-235
ISO 9001:2000 Registered
USP Structural Connectors®
in Montgomery, Livermore, Largo, and North Wilkesboro achieved registration of its quality system in accordance with the requirements of ISO 9001:2000
WARRANTY
United Steel Products Company warrants its products to be free from defects in material and workmanship. Said products are further warranted as to adequacy of design, provided products are used in strict accordance with United Steel Product Company's current published design limits and are installed in a workmanlike manner. (Said warranties do not apply in the event products are cut, notched, welded, drilled or in any way altered). No warranty applies if deterioration occurs due to environmental conditions. United Steel Products Company's obligations under this warranty shall be limited to the replacement or repair of those products demonstrated to be defective. Such remedy shall constitute Customer's sole and exclusive remedy and Customer hereby agrees that no other remedy (including, but not limited to claims for INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, OR ANY CAUSE, LOSS, ACTION, CLAIM OR DAMAGE, INCLUDING LOSS OF TIME, WHATSOEVER, OR INJURY TO PERSON OR PROPERTY OR ANY OTHER CONSEQUENTIAL DAMAGE OR INCIDENTAL OR ECONOMIC LOSS) shall be available to Customer whether said claims be asserted on the basis of warranty, negligence, strict liability or otherwise. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ALL SUCH OTHER WARRANTIES BEING HEREBY EXPRESSLY EXCLUDED.
Customer Service / Technical Assistance
Livermore, CA Office Montgomery, MN Corporate Office
1-800-227-0470
1-800-328-5934
Company History
The USP Structural Connectors Anchor to Connector Guide combines the structural connectors from the Full Line Catalog that are used to connect members to concrete with the corresponding anchoring products from the Anchoring Systems Technical Design Guide. Company History USP Structural Connectors® (United Steel Products Company) has been designing, manufacturing, and marketing construction hardware for over 50 years. The company's experience in marketing, engineering, and superior customer service has allowed USP to be the leader in developing new structural connectors for a changing construction industry. In February 2004, USP acquired Covert Operations, Inc. a manufacturer of adhesive and undercut anchoring and crack repair systems. Covert Operations has focused on providing high quality anchoring and epoxy products to meet the tough demands of the Western U.S. seismic engineering community for the last 15 years. The company brings extensive experience in the industrial, commercial, university, and heavy civil markets. Burnsville, MN Corporate Office 14035 South Cross Drive Suite 200 Burnsville, MN 55306 Phone: 1-800-328-5934 Phone: 1-952-898-8772 Fax: 1-507-364-8762
Livermore, CA Office
3
USP Operations Include: · Nine strategically placed manufacturing and warehousing locations. · In-house quality control and testing with independent, third-party plant inspection, and test witnessing. · On staff licensed professional engineers. · Our National Factory Technical Sales Force is ready to help with application questions. · Ongoing regional and national code evaluations as products are developed. Product Questions & Answers The Customer Service / Technical Assistance staff is ready to answer your questions and help solve your connector related problems. Our staff can assist you in developing economical solutions for your structural connection problems. When calling for Technical Assistance, please have the following information ready: When calling for Technical Assistance, please have the following information ready: ·Which USP product are you using? ·What is the post material and application? ·What is the load requirement? ·What are the concrete edge and end distances? ·What is the compressive strength of the concrete?
2150 Kitty Hawk Road Livermore, CA 94551-9522 Phone: 1-800-227-0470 Phone: 1-925-449-4100 Fax: 1-925-373-9213
Largo, FL Office
11910 62nd Street North Largo, FL 33773-3705 Phone: 1-800-328-5934 Phone: 1-727-536-7891 Fax: 1-727-535-8199
Thornhill, Ontario Office
221 Racco Parkway Thornhill, Ontario L4J 8X9 Phone: 1-800-387-3589 Phone: 1-905-669-6955 Fax: 1-905-669-1563
www.USPconnectors.com e-mail: info@USPconnectors.com
© Copyright 2005 United Steel Products Company USP1017-051
4
Edge and Distance Effects
Reduced concrete edge and end conditions reduce the capacity of anchors. Tables in this publication include the reduced and/or tested capacities at the close edge and end conditions as listed in the tables.
UPLIFT
SHEAR
C2 W C1
INSTALLATION 1: STEMALL-EDGE, END, AND WALL WIDTH CONDITIONS
C2 C1
INSTALLATION 2: SLAB EDGE AND END CONDITIONS (2 EDGES)
C2 C1
INSTALLATION 3: SLAB EDGE CONDITION ONLY (1 EDGE)
C2 C1
INSTALLATION 4: NO SLAB EDGE OR END CONDITION
Customer Service / Technical Assistance
Livermore, CA Office Montgomery, MN Corporate Office
1-800-227-0470
1-800-328-5934
Anchoring Systems
CIA-GEL 7000 Epoxy Anchoring System
CIA-GEL 7000 is a 2-component, 100% solids, 1 to 1 ratio, non-shrink, low-odor, moisture insensitive structural epoxy. It is dispensed throught a static mixing nozzle to ensure complete mixing. Meets ASTM C-881 requirements. ICBO/ICC ES Listed, City of L.A. RR, plus many State DOT listings.
CIA-GEL 7000 CARTRIDGES
5
Catalog Number
GEL-10 GEL-22
Description
CIA-GEL 7000 10 FL. OZ. Cartridge CIA-GEL 7000 22 FL. OZ. Cartridge
Qty/Package
12 12
CIA-GEL 7000 DISPENSING TOOLS
Catalog Number
HDT-22 PDT-22 CIA-GEL 7000 NOZZLES
Description
CIA-GEL 7000 22 FL. OZ. Hand Dispensing Tool CIA-GEL 7000 22 FL. OZ. Pneumatic Tool
Qty/Package
1 1
Catalog Number
CNOZ12
Description
1/2" Step Down Mixing Nozzle
Qty/Package
6
CIA-EA Epoxy Acrylate Anchoring System
CIA-EA is a 2-component, all weather, 100% solids, non-shrink, low-odor, moisture insensitive structural epoxy acrylate. It is dispensed throught a static mixing nozzle to ensure complete mixing. ICBO/ICC ES Listed, City of L.A. RR. Cures at temperatures down to 5 F.
CIA-EA CARTRIDGES
Catalog Number
ACR-5 ACR-12
Description
CIA-EA 5 FL. OZ. Cartridge w/Nozzle CIA-EA 12 FL. OZ. Cartridge
Qty/Package
12 12
CIA-EA DISPENSING TOOLS
Catalog Number
HDT-12
Description
CIA-EA 12 FL. OZ. Hand Dispensing Tool
Qty/Package
1
CIA-EA NOZZLES
Catalog Number
ACRNOZ
Description
CIA-EA Single Piece Mixing Nozzle
Qty/Package
6
DUC Ductile Undercut Anchors
DUC Ductile Undecut Anchors are mechanical undercut anchors that are installed in an undercut hole and transfer load through bearing rather than friction, similar to a cast-in-place bolt. Meets ACI 355.2 requirements. ICBO/ICC ES Listed, City of L.A. RR.
Refer to the Current Full Line Catalog and Anchoring Systems catalog for complete information.
www.USPconnectors.com e-mail: info@USPconnectors.com
© Copyright 2005 United Steel Products Company USP1017-051
6
Bearing Plates  BP12, LBP12-TZ, & HBPS12 series
Concrete Anchor Diameter: 1/2 100% Shear: N/A Normal Weight Concrete Refer to the current USP Full Line Catalog and Anchoring Systems Catalog for complete information.
Installation 1 Â Minimum End (c2) and Minimum Edge (c1) Dist. for Stemwalls (8) Edge End Anchor Product Embedment Distance Distance Capacity (lbs) CIA-GEL 7000 4-1/2 1-3/4 5 1465 CIA-EA 4-1/2 1-3/4 5 1055 DUC N/A N/A N/A N/A N/A Installation 2 Â Minimum End (c2) and Minimum Edge (c1) Dist. for Slabs Edge End Anchor Product Embedment Distance Distance Capacity (lbs) CIA-GEL 7000 4-1/2 1-3/4 5 1465 CIA-EA 4-1/2 1-3/4 5 1055 DUC N/A N/A N/A N/A N/A Installation 3 Â Minimum Edge (c1) Distance only in Slabs Edge End Product Embedment Distance Distance CIA-GEL 7000 4-1/2 1-3/4 5 CIA-EA 4-1/2 1-3/4 N/A DUC N/A N/A N/A N/A Installation 4 Â No Minimum Edge or End Distance in Slabs Product Embedment 4-1/2 4-1/2 4-1/2 Edge Distance 6-3/4 6-3/4 4-1/2 End Distance 6-3/4 6-3/4 5 Anchor Capacity (lbs) 1465 1055 N/A Anchor Capacity (lbs) 3555 2560 3910
Capacities for connectors are taked from the current USP Full Line Catalog. Refer to USP's Full Line catalog for all requirements and information including code report numbers, proper installation, post thickness, deflections, etc. 100% Uplift load capacity for the connector and the anchors listed above have not been increased for short-term loading. Allowable capacities for most products may be increased in accordance with Section 1612.3.3 of the UBC of Section 1605.3.2 of the 2000 IBC for wind and seismic loading. Please refer to the latest technical information and ICC/ICBO ES Reports for load increases allowed for each product.
CIA-GEL 7000 CIA-EA DUC 12-400
Installation 1
Installation 3
C2 W C1 Installation 2
C2 C1 Installation 4 C2
C2 C1 C1
Customer Service / Technical Assistance
Livermore, CA Office Montgomery, MN Corporate Office
1-800-227-0470
1-800-328-5934
Bearing Plates  BP58, LBP58 series
Concrete Anchor Diameter: 5/8 100% Shear: N/A Normal Weight Concrete Refer to the current USP Full Line Catalog and Anchoring Systems Catalog for complete information.
7
Installation 1 Â Minimum End (c2) and Minimum Edge (c1) Dist. for Stemwalls (8) Edge End Anchor Embedment Product Distance Distance Capacity (lbs) CIA-GEL 7000 5-3/4 1-3/4 7 2700 CIA-EA 4-1/2 1-3/4 6-3/4 1055 DUC N/A N/A N/A N/A N/A Installation 2 Â Minimum End (c2) and Minimum Edge (c1) Dist. for Slabs Edge End Anchor Product Embedment Distance Distance Capacity (lbs) CIA-GEL 7000 5-3/4 1-3/4 7 2700 CIA-EA 4-1/2 1-3/4 6-3/4 1055 DUC N/A N/A N/A N/A N/A Installation 3 Â Minimum Edge (c1) Distance only in Slabs Edge End Product Embedment Distance Distance CIA-GEL 7000 5-3/4 1-3/4 7 CIA-EA 4-1/2 1-3/4 6-3/4 DUC N/A N/A N/A N/A Installation 4 Â No Minimum Edge or End Distance in Slabs Product Embedment 5-1/2 5-3/4 4-1/2 Edge Distance 6-1/2 7 4-1/2 End Distance 6-1/2 7 5 Anchor Capacity (lbs) 2700 1055 N/A Anchor Capacity (lbs ...