Need help using a product?
|
|
|
|
User manual WHIRLPOOL 8205139-D-WH
Diplodocs help download the user guide WHIRLPOOL 8205139-D-WH .
This product, although classified under the brand WHIRLPOOL, may have been manufactured by AMANA, BAUKNECHT, ESTATE, GLADIATOR, INSPERIENCE, JENN-AIR, KITCHENAID, MAGIC CHEF, MAYTAG, ROPER after mergers, acquisitions, or a change in name.
Preview of the first 3 pages of manual
You either have JavaScript turned off or an old version of Adobe Flash Player Get the latest Flash Player.
Manual abstract: user guide WHIRLPOOL 8205139-D-WH
Detailed instructions for use are in the User's Guide. ®
Microwave Hood Combination
OVERALL DIMENSIONS
PRODUCT MODEL NUMBERS GH5176XP GH5184XP GH6177XP GH6178XP
Electrical: A 120 Volt, 60 Hz, AC only, 15- or 20-amp fused electrical supply (or circuit breaker) is required. (A time-delay fuse or circuit breaker is recommended.) It is recommended that a separate circuit serving only this appliance be provided.
17¹/" (43.5 cm)
15/" (40.3 cm)
15 (39 ³/" .1 c m)
29/"
(75.9 c
m)
CABINET OPENING DIMENSIONS VENTING REQUIREMENTS
A 3¹/" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used. The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. For best performance, use no more than three 90° elbows. To calculate the length of the system you need, add the equivalent length for each vent piece used in the system. See the following examples:
A
B
A
B
C
30" (76.2 cm) min.
12" (30.5 cm) min. 14" (35.6 cm) max.
66" (167.6 cm) min.
D
E
F
G
A. Rectangular to round transition piece: 3¹/" x 10" to 6" = 5 ft (8.3 x 25.4 cm to 15.2 cm = 1.5 m) B. Roof cap: 3¹/" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m) C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m) D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m) E. Wall cap: 3¹/" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m) F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m) G. 90° flat elbow: 3¹/" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A
6 ft (1.8 m)
A. 2" x 4" wall stud B. Grounded 3 prong outlet
B
3¹/" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total
A
2 ft (0.6 m) 2 ft (0.6 m) 6 ft (1.8 m)
B
C
D
C
A. One 3¹/" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m) B. 1 wall cap = 40 ft (12.2 m) C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
A. Two 90° elbows = 20 ft (6.1 m) B. 1 wall cap = 40 ft (12.2 m) C. 1 rectangular to round transition piece = 5 ft (1.5 m) D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8205139 08-23-05
...
|