9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your XTA D2 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on XTA D2

User manual XTA D2

Diplodocs help download the user guide XTA D2 .

Download the complete user guide (1143 Ko)





Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide XTA D2

Detailed instructions for use are in the User's Guide.

D2 Quick Reference THINGS YOU NEED TO KNOW... ü BOLD MEANS HOLD! Any functions that would produce possible unexpected level changes at the outputs are protected by a `press and hold' action and printed in BOLD on the panel. These functions are: Changing MODE between `cut below' and `cut above'; Switching middle band into FULL RANGE mode; Enabling the sidechain LISTEN function on any band. ü The meters show level, in dB, from the clipping point of the unit ­ when the METER switch is set to `IN' the meters show level, in dB, from clipping the input converter. Set to `OUT' they show headroom available at the output ­ the DAC. ü When in Shelf mode, the outer bands only become full range when the Freq is set to 20k and 20Hz respectively. ü Make-up gain is automatically bypassed when the Master switch is off. ü Only one Listen can be active at any time ­ selecting another band cancels the last one. ü The Listen LED always flashes when any Listen switch is enabled. Listen is not automatically turned off if the unit is switched off and on. ü When the unit is bypassed, all its metering and status LEDs will dim. All metering will continue to function. Page 2 D2 Operators Manual Contents D2 Quick Reference Important Safety Information Thanks Unpacking the D2 Introduction Features 2 4 5 5 6 6 Front Panel Familiarisation Rear Panel Connections Operating the D2 Switching the unit on and start-up procedure Press-and-hold Keys Minimum and maximum control positions 7 9 10 10 10 10 What is Dynamic EQ? Setting the Attack and Release times Operating Notes Operating Level Grounding 11 13 14 14 14 Specifications Warranty Options and Accessories 15 16 16 D2 Operators Manual Page 3 An example of this equipment has been tested and found to comply with the following European and international Standards for Electromagnetic Compatibility and Electrical Safety: Radiated Emissions (EU): RF Immunity (EU): Electrical Safety (EU): EN55013-1 (1996) EN55103-2 (1996) RF Immunity, ESD, Burst Transient, Surge, Dips &Dwells EN60065 (1993) Important Safety Information Do not remove Covers. No user serviceable parts inside, refer servicing to qualified service personnel. This equipment must be earthed. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN DO NOT EXPOSE TO RAIN OR MOISTURE ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS ENLEVER NE PAS EXPOSER A LA PLUIE NI A L'HUMITE It should not be necessary to remove any protective earth or signal cable shield connections. Do not defeat the purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade and the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Only use this equipment with an appropriate mains cord. In the USA the cord should comply with the requirements contained in the Standard for Cord Sets and Power Supply Cords, UL 817, be marked VW-1, and have an ampacity rating not less than the marked rating of the apparatus. Page 4 D2 Operators Manual Thanks Thank you for choosing the XTA D2 Stereo Dynamic EQ for your application. Please spend a little time reading through this manual, so that you obtain the best possible performance from the unit. All XTA products are carefully designed and engineered for cutting-edge performance and world-class reliability. If you would like further information about this or any other XTA product, please contact us. We look forward to hearing from you in the near future. Unpacking the D2 After unpacking the unit, please check it carefully for any damage. If any is found, immediately notify the carrier concerned - you, the consignee, must instigate any claim. Please retain all packaging in case of future re-shipment. D2 Operators Manual Page 5 Introduction The D2 is a powerful DSP based audio dynamics processor, ideally suited for live sound applications, where it combines the accessibility and immediacy of a pure analogue design with the quality and accuracy of a digital design in a compact 1U unit. To achieve this, the D2 has an analogue control surface, following the `one control ­ one function' philosophy and a pure digital signal path, with 24-bit conversion, 40-bit internal processing and a professional 48kHz sampling rate. The D2 is also available with optional AES/EBU digital inputs and outputs. Features Three bands of full range dynamic equalisation on each channel. Independent control of envelope and frequency for each equaliser band. `Outer' bands can be set to high and low shelving responses respectively, with the option of working in full-range if required. Separate `Listen' facility for each band to easily guage its contribution to the overall channel's sound. Each band is individually bypassable for complete control, with an overall channel master. Additional full-range compressor is included. AES/EBU Digital input and output interfaces are available as an option. Input and output balancing transformers are also available as an option. Page 6 D2 Operators Manual Front Panel Familiarisation Level Meter: Dependant on the setting of the `METER' switch, this will display the instantaneous available headroom, at either the input to the channel (analogue to digital converter) or the output from the channel, post compressor (digital to analogue converter). Master Key: Switches the entire channel on/off ­ LED illuminated when processing is active. All metering and status LEDs for dim when the unit is bypassed. Make-up Gain Control: Compensate for gain reduction by adding up to +15dB of additional gain. Meter Key: Select what the level meter shows ­ either input headroom or output headroom. Still active even when the channel is bypassed. Full Range Compressor Section: Threshold Control: Gain Reduction Meter: The red LEDs indicate progressively more gain reduction (compression) up to 15dB. Response Key (Fast/Med/Slow): Select the attack/release times ­ fast typically for transient control, and medium/slow for overall level control. Fast is selected when both LEDs are OFF. Ratio Key: Set the degree of compression to take place, once the signal exceeds the threshold, cycling through LOW (both LED's OFF), MEDIUM and HIGH. Active Key: Bypass just the full range compressor stage. Dynamic EQ Bands: Threshold Control: Adjust the onset of dynamic control in each particular band, from ­30dBu to +22dBu MODE Key: Select whether gain reduction is to occur either above the threshold, or below. Hold key to change modes. D2 Operators Manual Page 7 Band Frequency Control: Select the centre (or corner in the case of shelving response) frequency of the band to be controlled. 'Q' Control: Select how wide the band of frequencies to be controlled is, from 2 Octaves (bandwidth = 0.5 ­ wide) to 0.125 Octaves (bandwidth = 8 ­ narrow) . Gain Reduction Meter: The red LEDs indicate progressively more gain reduction up to 15dB. LISTEN Key: Switches the output of the sidechain filter into the main signal path, so that the required range of frequencies may be more easily selected. LED flashes as a reminder that this is selected. Shelf Key: Switch between a bandpass filter (with variable bandwidth) and a shelving response. Full Range LED: To enable the band to work as a full range compressor/expander, press the SHELF, and then turn the frequency control fully clockwise/anti-clockwise (for bands 1 & 3 respectively). Page 8 D2 Operators Manual Rear Panel Connections Power Switch: turns the units mains supply off and on. Mains Fuse: located in a finger-proof holder adjacent to the mains inlet. A spare fuse is also located in this holder. Mains Inlet: connected via a standard IEC socket. Audio In-Out: 3 pin XLR sockets are provided for each channel. All are fully balanced, pin 2 hot, 3 cold, 1 screen. Always replace the fuse with the correct type and rating as shown on the rear panel legend. D2 Operators Manual Page 9 Operating the D2 Operation of the D2 is very straightforward, but there are a few points worth noting which, once understood, will make using the unit even easier. Switching the unit on and start-up procedure After plugging in the power and switching the power on suing the rear panel switch, confirmation is quickly given that all is well by various status LEDs illuminating almost immediately after power-up. These will include, as a minimum, METER (In/Out); MODE (Cut Above/Below); and Band Active LEDs . The gain reduction will fully illuminate and, after the bypass relays disengage, begin to `count down' accompanied by the output level fading up to normal operating level. The entire process is complete when the input/output meters and gain reduction begin to operate normally. This whole start-up procedure only takes a few seconds. Press-and-hold Keys The legending on the front panel alerts the user to the fact that several keys require a `press and hold' action to initiate them. These keys relate to functions that could accidentally introduce large changes of level at the outputs, causing undesirable effects and possible damage. These keys have their function marked in BOLD (and a different font) to make it clear that they will only change state if the key is held in for a time. The keys in question are... MODE ­ switching between `cut below' mode and `cut above' mode (See page nn) LISTEN ­ switching output to monitor any band's sidechain EQ signal (See page nn) FULL RANGE­ switching middle band into full range mode (See page nn) Minimum and maximum control positions To ensure that the D2 is 100% accurate all of the time, and that what it says on the front panel is exactly what the unit is doing, it has been necessary to introduce `end-stops' on the controls. The extreme regions on each control marked with the curved line designate this entire region as relating to the parameter value shown. This is to compensate for the mechanical tolerances of the potentiometers. Page 10 D2 Operators Manual What is Dynamic EQ? Dynamic EQ is essentially a compressor or expander that can be set to respond and act upon only a certain range of frequencies. Its behaviour is dependent on the operating mode chosen: the operating modes are explained in detail below. Mode I: "Cut Above" Having selected the frequency band to work with, the dynamic eq will listen to this band and act upon it by cutting(compressing) any frequencies present in it that go above the predetermined threshold. Consider the example below where the threshold is set to ­20dB, and the selected frequency band is centred around 1kHz, with a `Q' of 1.0. Signals below the threshold will pass unaltered, but as increasing signal is applied, those frequencies centred around 1kHz will be cut or compressed. The ratio in the above example is set at 2:1 so, as with any compressor, the amount of gain reduction applied depends on how much the signal exceeds the threshold. The red line represents a signal at 0dB, which is 20dB above the threshold. At 1kHz, therefore, the signal has been compressed to ­10dB or 2:1. Uses of "Cut Above" mode. Traditional use of `frequency conscious' compression is to control or `tame' a certain band of frequencies within the program material. Insertion of EQ into the sidechain will make the compressor respond to the required band, but it will cause broadband compression of the signal, so any peaks will cause the entire signal to be compressed. This produces the familiar problem of dulling the material if it is bass-heavy, or causing unnecessary dips and changes in ambience when attempting to remove sibilance. The difference with dynamic EQ is that only the band selected is compressed. This means that it becomes possible to compress the low frequency content of material without affecting the high frequencies at all. The result is increased volume and perceived level with out sacrificing clarity. Any instance where the desired result is to control a band of frequencies, such as de-essing, or de-popping, without affecting the surrounding frequency ranges is an ideal use for this mode. D2 Operators Manual Page 11 Try de-essing with the filter centred at 8-9kHz, and a relatively narrow `Q' of about 4, attack 1mS, release 100mS. Mode II: "Cut Below" Having selected the frequency band to work with, the dynamic eq will listen to this band and act upon it by cutting any frequencies present in it that drop below the predetermined threshold. Consider the example below where the threshold is set to +10dB, and the selected frequency band is centred around 1kHz, with a `Q' of 1.0. Signals above the threshold will pass flat, but as the level decreases, those frequencies centred around 1kHz will be cut or expanded. The amount of gain reduction applied depends on how much the signal drops the threshold and the ratio set ­ a 2:1 ratio would mean that for every drop of 1dB ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.