Download user guide, user manual, owner manual and instructions guide
5 600 brands
1 870 000 user's guides
Search a brand
Advanced Search



Our partners wish to propose you the following products


Visit YAESU official site

User manual YAESU VP-1000

Diplodocs help download the user guide YAESU VP-1000.



Download the user manual YAESU VP-1000  
Download the complete
user guide (588 Ko)
Need help, support, reviews, tips or troubleshooting for your YAESU VP-1000 products ?

Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
User guide YAESU VP-1000

Detailed instructions for use are in the User's Guide.

YAESU VP-1000 AC POWER SUPPLY FOR THE VL-1000 LINEAR AMPLIFIER The VP-1000 is an external AC power supply for use with the VL-1000 Linear Amplifier, providing 48 Volts DC at up to 48 amperes for extended periods. Excellent regulation and conservative design assure the owner of many years of trouble-free operation, even in heavy duty applications, such as full power AM, FM, or RTTY transmission. A thermally switched cooling fan automatically activates during long periods of high current demand, to maintain a safe operating temperature in the power supply. An alarm signal output is provided to the VL-1000 to avoid damage in the event that excessive current, excessive voltage, or over-heating of the heatsink should occur. SPECIFICATIONS Output Voltage: DC +48 V -- , DC +12 V -- , DC -12 V -- ------Output Current: DC +48 V -- : 22 A (AC 100-200 V~) -- DC +48 V -- : 48 A (AC 200-240 V~) -- DC +12 V -- : 2.8 A --DC -12 V -- : 0.1 A --Input Voltage: AC 100-240 V~, 50-60 Hz Current Consumption: 15 A (AC 100-200 V~) 13 A (AC 200-240 V~) Operating Temperature Range: -10 °C-+50 °C Case Size: 410 x 135 x 369 mm (W x H x D) Weight: 14.6 kg (Approx.) Specifications are subject to change without notice. VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. SUPPLIED ACCESSORIES E 0 9 1 0 1 0 0 2 VERTEX STANDARD HK LTD. Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong DC Power Cable: T9021199 (2 meters) 1 Control Cable: T9101483 (2 meters) 1 INSTALLATION The power supply in the VP-1000 is capable of operation from 100 ~ 240 VAC at 50 or 60 Hz. If you have a choice between these two voltage ranges, use the higher voltage to minimize losses in the AC cable. Connect the supplied DC Power Cable between the VP-1000 OUTPUT jack and the VL-1000 DC 48V IN jack, and connect the supplied Control Cable between the VP-1000 CONTROL socket and the VL-1000 CONTROL socket. Turn the Circut Breaker on the VP-1000 rear panel ON, then turn the VP-1000 MAIN switch ON to activate the power supply. Always turn the VP-1000 Circut Breaker and MAIN switch on before turning on the VL-1000 POWER switch. To assure long life of the components, a primary consideration in setting up the VP-1000 is providing for adequate ventilation around the cabinet. The cooling system of the VP-1000 must be free to draw cool air in at the bottom of the chassis, and to expel warm air out of the rear panel. Provide a few centimeters of space around each side of the VP-1000. Avoid heating vents and window locations that could expose the VP-1000 to excessive direct sunlight, especially in hot climates. CIRCUIT DIAGRAM AC POWER CONNECTIONS The VP-1000 Power Supply does not require any transformer re-wiring, nor any changing of a switch position; the power supply will operate from either 230 or 120 Volt line voltages without configuration changes. However, the AC power cable/plug configuration will be somewhat different, depending on the country in which you purchased your power supply. In some countries, the VP-1000 is shipped with the standard 230 Volt connector appropriate for your location. In those areas where there are multiple 230 Volt connectors in common use, the VP-1000 is shipped without the power connector; one may be obtained at a local hardware or electrical supply store. Pictorial diagrams of the common 230 and 120 Volt AC connectors in use are shown below. When wiring your own connector, be absolutely certain to observe the proper polarity on the pin connections. Consult with an electrician if you have any doubts about your wiring! Be sure that your house wiring is capable of sufficient current capacity on the 230 Volt circuit to be used, especially if this circuit is shared with household appliances. It always is preferable to operate the VP-1000 from a dedicated 230 Volt circuit with its own circuit breaker. (U.S.A. version) USA PLUG UK PLUG European PLUG Australian PLUG (European version) (viewed from plug prong side)

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAESU VP-1000.

YAESU offer a product for which we do not have the user manual? Let us know what you are looking for: site Internet, histoire, actualité, filiales, site Internet, mode d'emploi, driver, avis des utilisateurs, meilleur prix des produits, forum d'assistance aux problèmes, annuaire des marques, annuaire des constructeurs, répertoire des marques, répertoire des constructeurs, site Internet de la marque, site Internet du constructeur

Diplodocs allows you to download user manual YAESU VP-1000, user guide YAESU VP-1000, instructions YAESU VP-1000, owner's manual YAESU VP-1000, online manual YAESU VP-1000.


Access web reviews YAESU VP-1000, , Radio.
Include the add-on to download manuals from your site, forum or blog Frequently Asked Questions Contact Diplodocs team Last searches
Last additions
Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.