9 562 brands
2 694 000 user's guides


Download your manual, it's FREE! Diplodocs allows you to download several types of document in order to best use your ZIBRO DX118 : user manual, user guide, instruction manual.
Search a brand
Advanced Search

Need help using a product?
Look at the reviews on ZIBRO DX118

User manual ZIBRO DX118

Diplodocs help download the user guide ZIBRO DX118 .

Download the complete user guide (896 Ko)




You may also download the following manuals related to this product:
ZIBRO DX118 MANUAL 2


Preview of the first 3 pages of manual

You either have JavaScript turned off or an old version of Adobe Flash Player
Get the latest Flash Player.
Manual abstract: user guide ZIBRO DX118

Detailed instructions for use are in the User's Guide.

D 112 - D 116 - DX 118 2 6 5 3 FIN GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO MANUEL D'UTILISATION KÄYTTÖOHJE OPERATING MANUAL ISTRUZIONI D'USO BRUKSANVISNING GEBRUIKSAANWIJZING INSTRUKCJA OBSLUGI BRUKSANVISNING KULLANIM KILAVUZU 2 12 22 32 42 52 62 72 82 92 102 112 4 > u 1 : = TR Dear Sir, Madam, Congratulations with the purchase of your dehumidifier. You have acquired a high quality product which will give you many years of pleasure, if you use it responsibly. Please read the user's manual first in order to ensure the optimum life span of your dehumidifier. On behalf of the manufacturer, we provide a two-year warranty on material- or manufacturing defects. Enjoy your dehumidifier. Yours sincerely, PVG International B.V. Customer Service Department 1 PLEASE READ THE USER'S MANUAL FIRST. 2 IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER. 4 52 IMPORTANT COMPONENTS ³ ³ · » Control panel Dry air outlet Removable water container Humid air inlet ´ ² Air filter Drainage spout (ø 13 mm) with cap ¶ º ¾ Castor Plug and cord Handle 4 53 SAFETY INSTRUCTIONS Install the device only when it complies with local regulations, by-laws and standards. The unit is only suitable for use in dry locations, indoors. Check the mains voltage and frequency. This unit is only suitable for earthed sockets, connection voltage 220-240 V. / 50 Hz. GENERAL · · · · · To obtain optimum performance from your dehumidifier, do not place it near a radiator or any other heat source. Ensure that all windows are closed in order to achieve maximum efficiency. The capacity of the dehumidifier depends on the temperature and the humidity in the room. At lower temperatures, less moisture will be removed. Ensure that the screen filter is kept clean. This prevents unnecessary power consumption and guarantees optimum efficiency. If the power supply has been interrupted, the defumidifier will restart after three minutes. The automatic delay protects the compressor. IMPORTANT The device MUST always have an earthed connection. If the power supply is not earthed, you may not connect the unit. The plug must always be easily accessible when the unit is connected. Read these instructions carefully and follow the instructions. Before connecting the unit, check the following: · · · · The voltage supply must correspond with the mains voltage stated on the rating label. The socket and power supply must be suitable for the current stated on the rating label. The plug on the cable of the device must fit into the wall socket. The device must be placed on a flat and stable surface. The electricity supply to the device must be checked by a recognised professional if you have any doubts regarding the compatibility. · · · · · · · · This device is manufactured according to CE safety standards. Nevertheless, you must take care, as with any other electrical device. Do not cover the air inlet and outlet grill. Empty the water reservoir before moving the unit. Never allow the device to come into contact with chemicals. Never spray the unit with or submerge in water Do not insert objects into the openings of the unit. Always remove the plug from the electric power supply before cleaning or replacing the unit or components of the unit. Never use an extension cable to connect the device to the electric power supply. If there is no suitable, earthed wall socket available, have one installed by a recognised electrician. 4 54 · · For safety reasons take care when children are in the surrounding of the device, as with any other electrical device. Have any repairs only carried out by a recognised service engineer or your supplier. Follow the instructions for use and maintenance as indicated in the user manual of this device. · · Always remove the plug of the unit from the wall socket when it is not in use. A damaged power cord or plug must always be replaced by a recognised electrician or your supplier. ATTENTION! · Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or allow it to come into contact with sharp edges. · Failing to follow the instructions may lead to nullification of the guarantee on this device. THE CONTROL PANEL This light indicates that the defrost function has been activated. This is necessary to prevent excessive formation of ice in the device. This light indicates that the water container is full. The device switches off automatically. ON-/OFF-button Ventilator-button Timer button Adjustment buttons hydrostat Heating button (DX118) 4 55 OPERATION DX118 1 2 Insert the plug in the wall outlet. Ensure that the water container has been positioned correctly. If the from the device and replace it in the correct position. -light switches on when you use the device for the first time, remove the water container 3 Press the -button to switch the dehumidifier on. The -adjustment buttons are used to set the desired humidity level. The hydrostat is adjustable from 30% to 85%. The value increases by 5% each time you press the button. The display indicates the set humidity (SET HUMIDITY) and also the relative humidity (ROOM HUMIDITY). The device starts to dehumidify when the relative humidity in the room is higher than the set value. The device switches off automatically when the set value is reached, and restarts when the humidity in the room rises again. 4 Select the ventilator speed by pressing the (= low) and 5 (= high). -button. You can select two settings: The timer function enables you to switch the device off after a certain time. The operating time can be set between 1 and 12 hours with the -button. Every time you press the button, the running time is extended by 1 hour. This will be shown on the display. When the pre-set time has elapsed, the device will switch off. 6 The dehumidifier DX118 is equipped with a heating function. Press the turn on the heating. By pressing the turned off. button to button again, the heating function will be 7 Press the -button to turn the device off. 4 56 AIR FILTER The D112, D116 and DX118 dehumidifiers are equipped with a 3-layer filter package to clean the circulated room air. The filters are delivered with a separately packed 3MTM HAF filter and an active carbon filter. These filters must be placed according to instructions before operating the dehumidifiers. 1 2 Screen filter; to remove bigger dust particles. 3MTM HAF filter; to remove unhealthy particles from the air such as pollen, bacteria, animal dander and dust. 3 Active carbon filter sheet; to remove odours. The filter holder on the backside of the unit can be opened. Active carbon filter and 3MTM HAF filter can be removed. Screen filter is part of the filter holder. 1 The screen filter has to be cleaned regularly with a vacuum cleaner to avoid blocking of the air flow. 2 The positive/negative electro statically charged 3MTM HAF filter is recommended to be changed every 3 months. Unusual dirt, construction work, pets, the presence of smokers and running the dehumidifier unit continuously can shorten the life time of the 3MTM HAF filter. New filter Recommended change of filter 3 The active carbon sheet can be cleaned with a vacuum cleaner when dusty but has to be changed at the same time as the 3MTM HAF filter. NOTE! · Never use the dehumidifier without the screen filter! · To run the unit without active carbon sheet and/or 3MTM HAF filter package does not bring any harm to the dehumidifier. In that case unhealthy dust is not removed. · Replacement filters are available at your dealer. WATER DRAINAGE When the water container is full, the will restart. -light switches on and the dehumidifier switches off automatically. Empty the container and replace it in the correct position. The device 4 57 If desired, it is possible to connect a drainage hose to the device for permanent water drainage. Follow these steps: 1 2 3 Unscrew the cap on the back. Remove the rubber stop from the drainage spout. Connect the drainage hose and ensure that the end of the hose is lower than the spout, otherwise the water will not drain and flooding may occur. 4 Place the end of the drainage hose in a water outlet. When you no longer wish to use the permanent water drainage, disconnect the drainage hose from the device. Push the rubber stop back into the drainage spout and replace the cap. Ensure that the water container is positioned correctly. CLEANING WARNING! Switch off the unit and remove the plug from the mains before cleaning the appliance or filter, or before replacing the filters. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. For maintenance of the filters, refer to Chapter "Air Filter". NOTE! Never use this dehumidifier without the screen filter. STORAGE If the machine will not be used for a long period of time, take the following steps: 1 Remove the plug from the socket and empty the container. Allow the container and the dehumidifier to dry completely. 2 3 Clean the air filter. Store the device in a dust-free location, preferably covered with a sheet of plastic. 4 58 TROUBLESHOOTING Check the following before contacting technical support: Problem Cause The powercord is not connected. The hydrostat setting is too low. The unit does not work. The water container is full. The water container has not been replaced correctly. The air filter is clogged. The device does not dehumidify. Remove the water from the container. Place the water container in the correct position. Clean the air filter. Solution Insert the plug into the wall outlet. Turn the hydrostat to the desired setting. The temperature or relative It is normal that the device does humidity in the room where the not dehumidify in these device is operating is too low. conditions. The room is too large. We recommend using a dehumidifier with a greater capacity. We recommend using a dehumidifier with a greater capacity. Reduce ventilation (e.g. close curtains and shut doors). The dehumidifier works, but reduces the relative There are too many sources of humidity insufficiently. humidity. There is too much ventilation. CONDITIONS OF WARRANTY There is a two-year warranty on your dehumidifier from the date of purchase. All material or manufacturing defects will be repaired free of charge. The following applies: · · · · · · All claims for compensation, including consequential damage, will not be entertained. Any repairs or replacement of components during the warranty period will not result in an extension of the warranty period. The warranty will expire if any alterations have been made, not genuine components have been fitted or if the dehumidifier has been repaired by a third party. Components subject to normal wear and tear, such as the air filter, are not covered by the warranty. The warranty is only valid on presentation of the original, unaltered, and datestamped purchase receipt. The warranty does not cover damage caused by actions that deviate from those as described in the user's manual or by neglect. 4 59 · Transportation costs and the risks involved during the transportation of the dehumidifier or components shall always be for the account of the purchaser. To prevent unnecessary expenses, we recommend that you always carefully read the user's manual first. If this does not provide a solution, take the dehumidifier to your distributor for repair. TECHNICAL SPECIFICATIONS Model Power consumption Power consumption (heating) Power supply Current (nom.) Dehumidifying capacity* Capacity water container Air flow (nom.)** For rooms up to** Operating range Automatic defrost Hydrostat Compressor type Refrigerant type / charge Pressure suction / discharge Dimensions (w x d x h ) Net weight Gross weight Sound pressure level ** Unit Protection Fuse rating r / gr bar mm kg kg dB(A) IP 13 15.0 40 42 IP 20 250V, T3.15A R134A / 140 gr kW kW V / Hz / Ph A L / 24h L m3/h m3 °C 120 50 - 75 1.8 12 D112 0.3 D116 0.3 220-240 / 50 / 1 1.8 16 3.5 120 70 - 105 5-32 Yes Yes Piston R134A / 140 gr 12 / 24 345 x 240 x 575 15.5 17.0 45 16 R134A / 190 gr 150 80 - 120 2.0 / 4.6 18 DX118 0.35 0.95 * Moisture removal at 32ºC, 80%RH ** To be used as indication Subject to change without prior notice. 4 60 PERFORMANCE GRAPH Nom. capacity [%] 100 80 % RH 75 60 % RH 50 50 % RH 25 0 3 6 9 12 15 18 21 24 27 30 33 T [°C] (to be used as indication only) Waste electrical products should not be disposed with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. Environmental information: This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It should only be serviced or dismantled by professional trained personnel. This equipment contains R134a refrigerant in the amount as stated in the table above. Do not vent R134a into atmosphere: R134a, ...

  Know our Partners   Frequently Asked Questions   Contact Diplodocs team   Last searches
Latest additions
  Sitemap
Brands starting with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #
Copyright © 2005 - 2008 - Diplodocs - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.